Contents
Chimney Stack Inspection and Common Defects
BEFORE SPECIFYING ANY CHIMNEY REPAIR WORK ON A LONDON VICTORIAN TERRACE, A THOROUGH INSPECTION OF THE CHIMNEY STACK IS REQUIRED — EITHER BY A SPECIALIST CHIMNEY CONTRACTOR, AN EXPERIENCED ROOFER, OR A BUILDING SURVEYOR — FROM A SCAFFOLD, CHERRY PICKER, OR DRONE INSPECTION PLATFORM — BECAUSE MANY CHIMNEY DEFECTS ARE NOT VISIBLE FROM GROUND LEVEL OR FROM WITHIN THE ROOF SPACE.
COMMON CHIMNEY STACK DEFECTS IN A LONDON VICTORIAN TERRACE: (1) FAILED POINTING (THE MORTAR JOINTS BETWEEN THE BRICKS OF THE CHIMNEY STACK HAVE ERODED, CRACKED, OR FALLEN OUT — TYPICALLY THE MOST COMMON DEFECT IN A VICTORIAN CHIMNEY STACK BECAUSE THE ORIGINAL MORTAR WAS A LIME-BASED MORTAR WITH NO PORTLAND CEMENT — SOFT AND WATER-SOLUBLE IN WET CONDITIONS — THE MORTAR ERODES FROM THE FACE OF THE JOINT (TYPICALLY CALLED SPALLING OR WEATHERING) LEAVING A RECESS IN THE JOINT THAT ALLOWS WIND-DRIVEN RAIN TO PENETRATE BETWEEN THE BRICKS AND INTO THE CORE OF THE STACK — THE MOST IMMEDIATELY DANGEROUS SYMPTOM OF FAILED POINTING IS SATURATION OF THE STACK CORE IN FREEZING CONDITIONS — THE WATER IN THE SATURATED BRICKWORK FREEZES AND EXPANDS — CAUSING THE BRICK FACE TO SPALL OFF — CALLED FROST SPALLING — WHICH ACCELERATES THE STRUCTURAL DETERIORATION OF THE STACK); (2) FAILED FLAUNCHING (THE CEMENT OR LIME MORTAR BED THAT HOLDS THE CHIMNEY POTS IN POSITION ON TOP OF THE STACK — FLAUNCHING IS A SLOPED MORTAR COLLAR AROUND THE BASE OF EACH CHIMNEY POT THAT WEATHERPROOFS THE JUNCTION BETWEEN THE POT AND THE STACK TOP AND SHEDS RAINWATER AWAY FROM THE POT BASE — FAILED FLAUNCHING IS CHARACTERISED BY CRACKING, SHRINKAGE GAPS, OR PARTIAL DETACHMENT OF THE MORTAR BED — ALLOWING WATER TO ENTER AROUND THE BASE OF THE CHIMNEY POTS AND PENETRATE THE STACK); (3) FAILED LEAD FLASHING AT THE CHIMNEY/ROOF JUNCTION (THE LEAD SOAKERS AND STEP FLASHINGS WHERE THE CHIMNEY STACK EXITS THROUGH THE PITCHED ROOF SLOPE ARE CRITICAL WATERPROOFING ELEMENTS — FAILURE IS CAUSED BY: LEAD FATIGUE CRACKING FROM THERMAL CYCLING (LEAD EXPANDS AND CONTRACTS WITH TEMPERATURE — OVER 100+ YEARS THERMAL CYCLING FATIGUE CRACKS DEVELOP); LEAD THEFT (UNFORTUNATELY COMMON IN LONDON — FLAT SECTIONS OF LEAD SOAKER AND BACK GUTTER ARE TARGETED); MORTAR JOINTS CRACKING WHERE THE LEAD IS TURNED INTO THE MASONRY JOINTS; OR SIMPLE AGE AND CORROSION); (4) CHIMNEY POT DAMAGE (CRACKED, LEANING, OR MISSING POTS — THE CHIMNEY POTS ON A LONDON VICTORIAN TERRACE ARE TYPICALLY TERRACOTTA OR SALT-GLAZED STONEWARE — FROST DAMAGE AND DETERIORATION OF THE FLAUNCHING MORTAR BED CAN CAUSE POTS TO LEAN, CRACK, OR IN EXTREME CASES FALL — A SIGNIFICANT SAFETY HAZARD).
Lime Mortar Repointing: St Astier NHL 2 and NHL 3.5
CHIMNEY STACK REPOINTING REQUIRES THE CORRECT SPECIFICATION OF MORTAR — THE MORTAR FOR REPOINTING A VICTORIAN CHIMNEY STACK MUST MATCH THE SOFTNESS AND FLEXIBILITY OF THE ORIGINAL LIME MORTAR AS CLOSELY AS POSSIBLE — BECAUSE A MORTAR THAT IS TOO HARD OR TOO STRONG (TOO HIGH A PORTLAND CEMENT CONTENT) WILL NOT FLEX WITH THE THERMAL MOVEMENT OF THE CHIMNEY STACK AND WILL CAUSE THE BRICK FACES TO SPALL (THE RIGID CEMENT MORTAR PREVENTS THE BRICK FROM MICRO-MOVING WITH TEMPERATURE CHANGES AND THE STRESS IS TRANSFERRED INTO THE BRICK FACE RATHER THAN INTO THE MORTAR JOINT — CAUSING THE BRICK FACE TO DETACH).
ST ASTIER NHL 2 (NATURAL HYDRAULIC LIME — CLASS NHL 2 — STRENGTH CLASS 2.0 N/MM² MINIMUM AT 28 DAYS — CHAUX DE SAINT-ASTIER, SAINT-ASTIER, DORDOGNE, FRANCE — THE WORLD'S MOST RESPECTED PRODUCER OF NATURAL HYDRAULIC LIME MORTARS FOR CONSERVATION AND HERITAGE BUILDING WORK): NHL 2 IS THE SOFTEST OF THE ST ASTIER NATURAL HYDRAULIC LIME RANGE — THE RECOMMENDED MORTAR FOR REPOINTING SOFT OR HIGHLY PERMEABLE HISTORIC BRICKWORK (INCLUDING THE HANDMADE YELLOW LONDON STOCK BRICK OF VICTORIAN TERRACES WHERE THE BRICK COMPRESSIVE STRENGTH IS TYPICALLY 15-25 N/MM² — SIGNIFICANTLY LOWER THAN MODERN FACING BRICKS AT 30-50 N/MM²). TYPICAL MIX RATIO FOR CHIMNEY REPOINTING WITH ST ASTIER NHL 2: 1 PART NHL 2 : 2.5-3 PARTS WASHED SHARP SAND (BY VOLUME) — THE SHARP SAND PROVIDES THE AGGREGATE AND BODY OF THE MORTAR — THE NHL 2 IS THE BINDER. ST ASTIER NHL 3.5 (NATURAL HYDRAULIC LIME — CLASS NHL 3.5 — STRENGTH CLASS 3.5 N/MM² MINIMUM AT 28 DAYS — A STRONGER BINDER THAN NHL 2 — RECOMMENDED FOR THE MORE EXPOSED UPPER SECTIONS OF A CHIMNEY STACK WHERE A SLIGHTLY STRONGER MORTAR IS APPROPRIATE — THE STACK IS MORE EXPOSED TO DRIVING RAIN AND FREEZE-THAW CYCLES AT THE TOP): TYPICAL MIX RATIO FOR CHIMNEY REPOINTING WITH ST ASTIER NHL 3.5 (UPPER EXPOSED SECTIONS): 1 PART NHL 3.5 : 2.5-3 PARTS WASHED SHARP SAND. REPOINTING PROCESS (THE CORRECT REPOINTING TECHNIQUE FOR A VICTORIAN CHIMNEY STACK): (1) RAKE OUT THE EXISTING MORTAR TO A MINIMUM DEPTH OF 15MM (THE NEW POINTING MORTAR MUST BE AT LEAST 15MM DEEP TO PROVIDE A SUFFICIENT KEY AND WEATHER RESISTANCE — RAKING WITH A PLUGGING CHISEL AND CLUB HAMMER OR AN ANGLE GRINDER WITH A MORTAR RAKING DISC — THE ANGLE GRINDER MUST BE USED CAREFULLY TO AVOID CUTTING INTO THE BRICK FACES — BETTER FOR A CONTRACTOR TO USE A HAND CHISEL FOR WIDE JOINTS AND AN ANGLE GRINDER ONLY FOR NARROW JOINTS); (2) REMOVE ALL DUST AND LOOSE MATERIAL FROM THE RAKED JOINTS (STIFF BRUSH AND COMPRESSED AIR); (3) DAMPEN THE RAKED JOINTS BEFORE APPLYING THE NEW MORTAR (THE EXISTING BRICK MUST BE DAMP BUT NOT SATURATED — TO PREVENT THE DRY BRICK FROM ABSORBING TOO MUCH WATER FROM THE NEW MORTAR BEFORE IT HAS HYDRATED PROPERLY — DRY BRICKS CAUSE THE NHL MORTAR TO FAIL BY DEHYDRATION); (4) APPLY THE MORTAR IN TWO LAYERS (THE FIRST SCRATCH COAT — PRESSED FIRMLY INTO THE JOINT AND SCRATCHED TO PROVIDE A KEY FOR THE SECOND COAT — THEN THE FINISH COAT — APPLIED AFTER THE FIRST COAT HAS STIFFENED BUT BEFORE IT HAS FULLY HARDENED — TYPICALLY 2-4 HOURS AFTER THE FIRST COAT DEPENDING ON WEATHER CONDITIONS); (5) FINISH THE JOINT FACE (THE STANDARD FINISH FOR A VICTORIAN TERRACE CHIMNEY IS A FLUSH OR SLIGHTLY RECESSED WEATHER-STRUCK JOINT — THE MORTAR IS SMOOTHED WITH A TROWEL AT A SLIGHT ANGLE SO THAT THE TOP FACE OF THE JOINT IS PROUD AND THE BOTTOM FACE IS RECESSED — SHEDDING RAINWATER AWAY FROM THE BRICK FACE BELOW).
Flaunching Repair and Chimney Pots
FLAUNCHING IS THE MORTAR BED AND COLLAR THAT IS FORMED AROUND THE BASE OF EACH CHIMNEY POT AT THE TOP OF THE CHIMNEY STACK — IT SEALS THE JUNCTION BETWEEN THE CHIMNEY POT AND THE BRICK TOP OF THE STACK AND SHEDS RAINWATER AWAY FROM THE JUNCTION.
FLAUNCHING SPECIFICATION FOR A VICTORIAN CHIMNEY STACK: THE MODERN REPLACEMENT FLAUNCHING MORTAR FOR A VICTORIAN CHIMNEY STACK CAN BE SPECIFIED IN TWO WAYS — DEPENDING ON THE PHILOSOPHY OF THE REPAIRER AND THE EXTENT OF THE REPAIR: TRADITIONAL LIME FLAUNCHING (ST ASTIER NHL 3.5 — 1:2.5 SHARP SAND — THE MORE FLEXIBLE AND BREATHABLE OPTION — SLOWER TO DRY AND ACHIEVE FULL STRENGTH THAN OPC FLAUNCHING — BUT MORE COMPATIBLE WITH THE SOFT LIME BRICKWORK OF THE VICTORIAN STACK TOP — LESS LIKELY TO CRACK FROM THERMAL CYCLING); MODERN OPC (ORDINARY PORTLAND CEMENT) FLAUNCHING (BLUE CIRCLE MASTER CEMENT OR EQUIVAKENT — 1 PART OPC : 3-4 PARTS SHARP SAND — STRONGER, FASTER TO DRY, MORE MOISTURE-RESISTANT IN THE SHORT TERM — BUT LESS FLEXIBLE — MORE PRONE TO CRACKING FROM THERMAL CYCLING IN AN EXPOSED CHIMNEY LOCATION — THE STANDARD SPECIFICATION USED BY MOST GENERAL CONTRACTORS AND ROOFERS FOR FLAUNCHING REPAIR BECAUSE OPC MORTAR IS EASIER TO WORK AND FASTER TO CURE THAN NHL MORTAR). FLAUNCHING REPAIR PROCESS: (1) REMOVE THE EXISTING CHIMNEY POTS (CAREFULLY — GENTLY BREAKING THE OLD FLAUNCHING MORTAR WITH A BOLSTER CHISEL — THE POTS ARE TYPICALLY TERRACOTTA AND CAN BE REUSED IF UNDAMAGED); (2) CHIP OFF ALL THE OLD FLAUNCHING MORTAR FROM THE STACK TOP; (3) CLEAN THE STACK TOP AND DAMPEN; (4) APPLY NEW MORTAR BED (THE MORTAR BED THAT THE POT SITS IN — APPROXIMATELY 40-50MM DEEP); (5) SEAT THE POT IN THE MORTAR BED AND CHECK PLUMB; (6) APPLY THE FLAUNCHING COLLAR AROUND THE BASE OF THE EACH POT — THE FLAUNCHING SHOULD BE FORMED AS A SMOOTH, SLOPED COLLAR THAT SLOPES UPWARD TOWARD THE POT AND AWAY FROM THE STACK TOP EDGE — DIRECTING WATER TOWARD THE POT AND OVER THE EDGE OF THE STACK — NOT INTO THE JUNCTION). CHIMNEY POTS: WHERE THE EXISTING CHIMNEY POTS ARE CRACKED, MISSING, OR BEYOND REPAIR: REPLACEMENT POTS AVAILABLE FROM UK SUPPLIERS INCLUDING ARUNDEL CHIMNEYS (ARUNDEL FIREPLACE CENTRE — SPECIALIST VICTORIAN-REPRODUCTION TERRACOTTA POT SUPPLIER — RANGE INCLUDES THE CANNON HEAD, ROLL TOP, AND OCTAGONAL FLAT TOP STYLES MOST COMMON ON LONDON VICTORIAN TERRACES). CHIMNEY COWL (WHERE THE CHIMNEY IS NO LONGER IN USE — A CHIMNEY COWL OR RAIN CAP SHOULD BE FITTED TO PREVENT WATER ENTRY INTO THE FLUE WHILE ALLOWING THE FLUE TO BREATHE — RECOMMENDED COWL: SOLID FUEL TECHNOLOGY LEAD COWL OR A HIGH-QUALITY GRP COWL — A CAPPED-AND-VENTED COWL PREVENTS RAINWATER ENTERING WHILE MAINTAINING PASSIVE VENTILATION OF THE FLUE — REQUIRED BY PART F BUILDING REGULATIONS WHERE THE CHIMNEY SERVES A HABITABLE ROOM).
Lead Flashings and Soakers: Specification and Replacement
THE LEADWORK AT THE CHIMNEY/ROOF JUNCTION (THE JUNCTION BETWEEN THE CHIMNEY STACK AND THE PITCHED ROOF SLOPE — TYPICALLY A PLAIN TILE OR SLATE ROOF ON A LONDON VICTORIAN TERRACE) IS THE MOST CRITICAL WATERPROOFING DETAIL AT THE CHIMNEY — AND THE MOST COMMON SOURCE OF WATER INGRESS INTO THE UPPER FLOORS OF A LONDON VICTORIAN TERRACE WHERE THE CHIMNEY IS STILL STANDING.
LEAD SPECIFICATION (FROM LEAD SHEET ASSOCIATION — LSA — UK INDUSTRY BODY): BS EN 12588:2006 (THE EUROPEAN STANDARD FOR ROLLED LEAD SHEET FOR BUILDING PURPOSES — ALL LEAD SHEET USED IN UK RESIDENTIAL ROOFING SHOULD COMPLY WITH BS EN 12588): LEAD SHEET GRADES: CODE 3 (1.32MM THICK — MINIMUM WEIGHT 14.97 KG/M²): USED FOR SOAKERS (THE SMALL INDIVIDUAL LEAD FLASHINGS THAT INTERLEAVE WITH THE ROOF TILES OR SLATES AT THE CHIMNEY SIDES — THE SOAKERS ARE CUT FROM CODE 3 LEAD SHEET AND ARE FIXED UNDER EACH TILE/SLATE COURSE AT THE CHIMNEY SIDE — THEY PREVENT WATER PASSING BETWEEN THE TILE EDGE AND THE CHIMNEY MASONRY); CODE 4 (1.80MM THICK — 20.41 KG/M²): USED FOR STEP FLASHINGS (THE VISIBLE LEAD FLASHING STRIPS THAT STEP UP THE SIDE OF THE CHIMNEY IN LINE WITH THE TILE/SLATE COURSES — TUCKED INTO THE CHIMNEY MASONRY MORTAR JOINTS AND DRESSED DOWN OVER THE TOP OF THE SOAKERS), THE CHIMNEY APRON (THE SINGLE FRONT FLASHING AT THE DOWNSLOPE FACE OF THE CHIMNEY — DRESSED DOWN OVER THE TILES BELOW), AND THE BACK GUTTER (THE LEAD TRAY AT THE UPSLOPE FACE OF THE CHIMNEY — COLLECTING WATER RUNNING DOWN THE ROOF SLOPE AND DISCHARGING IT TO THE SIDE OF THE CHIMNEY); CODE 5 (2.24MM THICK — 25.40 KG/M²): USED FOR BACK GUTTERS ON WIDER CHIMNEY STACKS WHERE A HEAVIER GAUGE IS REQUIRED. LSA STANDARD: THE LEAD SHEET ASSOCIATION'S RECOMMENDED PRACTICE FOR FLASHINGS AT CHIMNEY STACKS ON PLAIN TILE OR SLATE ROOFS SETS OUT THE DETAILED SPECIFICATIONS FOR THE DIMENSIONS, OVERLAPS, AND FIXING DETAILS OF EACH LEAD ELEMENT — THE LSA MANUAL IS THE DEFINITIVE UK REFERENCE FOR LEADWORK SPECIFICATION IN RESIDENTIAL ROOFING.
Access, Scaffold, and Chimney Repair Costs
CHIMNEY STACK REPAIR REQUIRES SAFE ACCESS TO THE CHIMNEY — THE CHOICE OF ACCESS PLATFORM AFFECTS THE COST AND THE QUALITY OF WORK THAT CAN BE ACHIEVED.
SCAFFOLD (THE MOST COMPREHENSIVE AND SAFEST ACCESS METHOD — REQUIRED FOR FULL REPOINTING AND LEADWORK REPLACEMENT — THE SCAFFOLD IS ERECTED AROUND AND OVER THE CHIMNEY STACK PROVIDING A FULLY BOARDED WORKING PLATFORM AT AND ABOVE CHIMNEY LEVEL — THE CONTRACTOR CAN WORK SAFELY ON ALL FOUR FACES OF THE STACK): SCAFFOLD SUPPLY AND ERECT/STRIKE (INNER LONDON — OVER THE REAR OR FRONT SLOPE OF A TWO-STOREY LONDON VICTORIAN TERRACE TO CHIMNEY HEIGHT — TYPICALLY 2-4 WEEK HIRE): APPROXIMATELY £1,200-2,500 (DEPENDING ON CHIMNEY HEIGHT, LOCATION, AND LONDON BOROUGH ACCESS RESTRICTIONS). CHERRY PICKER (BOOM LIFT — A SELF-PROPELLED ELEVATING WORK PLATFORM — MOBILE WHEELED UNIT THAT CAN BE DRIVEN ONTO THE PAVEMENT OR INTO THE REAR GARDEN): HIRE RATE (DAY HIRE — LONDON — 16M OR 20M WORKING HEIGHT — SUFFICIENT FOR A STANDARD TWO-STOREY VICTORIAN TERRACE CHIMNEY): APPROXIMATELY £500-900 PER DAY (CHERRY PICKER + OPERATOR FROM A PLANT HIRE COMPANY — NOT SUITABLE FOR ALL LOCATIONS — REQUIRES CLEAR ACCESS AND HARD STANDING ADJACENT TO THE BUILDING).
CHIMNEY REPAIR COSTS (LONDON 2025 — SPECIALIST CHIMNEY CONTRACTOR OR EXPERIENCED ROOFING CONTRACTOR — SUPPLY AND FIT — INCLUDING ACCESS SCAFFOLD OR CHERRY PICKER):
CHIMNEY REPOINTING ONLY (FULL REPOINT OF A STANDARD TWO-POT VICTORIAN TERRACE CHIMNEY STACK — ST ASTIER NHL 3.5 — INCLUDING RAKING OUT AND REPOINTING ALL FOUR FACES — ACCESS BY SCAFFOLD): APPROXIMATELY £600-1,500 (EXCLUDING SCAFFOLD — ADD £1,200-2,500 FOR SCAFFOLD IF NOT ALREADY ERECTED FOR OTHER ROOF WORKS — THE ECONOMICS OF CHIMNEY REPAIR STRONGLY FAVOUR COMBINING CHIMNEY REPAIR WITH OTHER ROOF REPAIR OR RE-ROOFING WORKS THAT REQUIRE SCAFFOLD — AVOIDING THE COST OF A SEPARATE SCAFFOLD JUST FOR THE CHIMNEY). FLAUNCHING REPAIR ONLY (REMOVE AND REPLACE FLAUNCHING ON A TWO-POT CHIMNEY — OPC MORTAR — ACCESS BY CHERRY PICKER ONE DAY): APPROXIMATELY £300-700 (INCLUDING CHERRY PICKER DAY HIRE). FULL CHIMNEY REPAIR (REPOINTING + FLAUNCHING + LEAD FLASHING REPLACEMENT — COMPLETE CHIMNEY OVERHAUL — ACCESS BY SCAFFOLD): APPROXIMATELY £2,000-5,000 (INCLUDING SCAFFOLD — SUPPLY AND FIT — DEPENDING ON CHIMNEY SIZE AND CONDITION). LEADWORK REPLACEMENT ONLY (REMOVE OLD LEAD FLASHINGS — SOAKERS, STEP FLASHINGS, APRON, BACK GUTTER — NEW CODE 3/4 LEAD — ACCESS BY SCAFFOLD): APPROXIMATELY £800-2,000 (EXCLUDING SCAFFOLD — DEPENDING ON CHIMNEY WIDTH AND STACK SIZE).
Frequently Asked Questions
What mortar should I use for repointing a Victorian chimney stack in London?▼
What is flaunching and how often does it need replacing on a London Victorian terrace?▼
What lead code should be used for chimney flashings on a London Victorian terrace?▼
Can I use a cherry picker instead of scaffold for chimney repair?▼
How much does chimney repair cost in London?▼
Important Note
This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. RCB Design & Build offers free initial consultations — book your free survey.