Contents
Understanding the Floor Condition in a Victorian Terrace
BEFORE ANY LEVELLING WORK, THE EXISTING FLOOR CONDITION MUST BE ASSESSED. THE TYPE OF FLOOR STRUCTURE DETERMINES WHICH LEVELLING SYSTEM IS APPROPRIATE:
GROUND FLOOR — SUSPENDED TIMBER (MOST COMMON IN LONDON VICTORIAN TERRACES): THE ORIGINAL GROUND FLOOR CONSTRUCTION IS SUSPENDED PINE BOARD ON TIMBER JOISTS WITH A SUB-FLOOR VOID BELOW (VENTILATED VIA AIR BRICKS IN THE EXTERNAL WALLS). THIS FLOOR TYPE: - IS NOT SUITABLE FOR DIRECT INSTALLATION OF HEAVY CERAMIC OR STONE TILES (FLEXION IN THE TIMBER STRUCTURE CAUSES TILE AND GROUT CRACKING) - IS SUITABLE FOR ENGINEERED TIMBER, LVTILES (LVT), CARPET, AND SOFTWOOD BOARDS - CAN BE MADE SUITABLE FOR TILES BY OVERLAYING WITH 18-22MM CEMENT BOARD (HARDIE BACKER — SCREWED AT 150MM CENTRES TO THE JOISTS) + FLEXIBLE TILE ADHESIVE (BAL RAPIDFLEX, MAPEI GRANIRAPID C2FTE) - UNEVENNESS IN SUSPENDED TIMBER FLOORS IS CORRECTED BY PACKING INDIVIDUAL BOARDS THAT ARE LOW (USING HARDBOARD PACKING STRIPS) OR BY OVERLAYING WITH 12MM PLYWOOD (BS EN 636 — EXTERNAL GRADE — SCREWED AT 200MM CENTRES) BEFORE CEMENT BOARD
GROUND FLOOR — SOLID CONCRETE OR BEAM-AND-BLOCK (LATER ADDITIONS — KITCHEN EXTENSIONS, REAR ADDITIONS): CONCRETE SLABS IN EXTENSIONS AND LATER REAR ADDITIONS: - TYPICALLY HAVE SURFACE VARIATIONS OF 5-15MM ACROSS A 2M STRAIGHT-EDGE - ARE SUITABLE FOR SELF-LEVELLING COMPOUND (SLC) TO CORRECT SURFACE IRREGULARITIES (UP TO 10-15MM DEPTH IN ONE POUR — THICKER LAYERS REQUIRE MULTIPLE POURS OR SCREED) - MAY HAVE EXISTING DPM (DAMP-PROOF MEMBRANE — POLYTHENE 1200 GAUGE) BELOW OR NOT — CHECK FOR DAMP BEFORE APPLYING SLC
UPPER FLOORS — TIMBER JOIST CONSTRUCTION: FIRST FLOOR AND ABOVE IN A VICTORIAN TERRACE IS ALMOST ALWAYS SUSPENDED TIMBER JOISTS: - ORIGINAL PINE BOARDS 150-225MM WIDE WITH GAPS BETWEEN BOARDS (NATURAL SHRINKAGE OVER 100+ YEARS) - SUITABLE FOR OVERLAY WITH 12MM PLYWOOD (GLUED AND SCREWED) TO CREATE A FLAT, GAP-FREE SUBSTRATE FOR LVT, ENGINEERED TIMBER, CARPET, OR VINYL - FOR TILES ON UPPER FLOORS: 18MM HARDIE BACKER OVER THE EXISTING BOARDS + FLEXIBLE ADHESIVE — AND STRUCTURAL ASSESSMENT IF TILES ARE LARGE/HEAVY FORMAT (DEAD LOAD OF TILES + ADHESIVE ON AN UPPER FLOOR MUST BE WITHIN THE JOIST\'S STRUCTURAL CAPACITY)
Self-Levelling Compound and Screed Systems
ONCE THE SUBSTRATE IS ASSESSED AND PREPARED, THE APPROPRIATE LEVELLING SYSTEM IS SELECTED:
SELF-LEVELLING COMPOUND (SLC) — FOR SURFACE CORRECTION UP TO 10-15MM: SLC IS A FLOWABLE CEMENTITIOUS OR ANHYDRITE-BASED COMPOUND THAT SELF-LEVELS WHEN POURED AND SPREAD. IT PRODUCES A VERY FLAT, SMOOTH SURFACE SUITABLE FOR ALL FLOOR FINISHES.
RECOMMENDED PRODUCTS: - ARDEX K 15 DEEP BED SELF-LEVELLING COMPOUND: CAN BE APPLIED 3-20MM IN A SINGLE POUR. WALKABLE IN 3-4 HOURS. SUITABLE FOR TILES, LVT, ENGINEERED TIMBER AFTER FULL CURE (24-48 HOURS). A VERY WIDELY USED PRODUCT IN LONDON RENOVATIONS. - MAPEI ULTRAPLAN ECO: 2-20MM DEPTH. FAST-SETTING (WALKABLE 2-3 HOURS, TILING IN 3-4 HOURS). LOW-EMISSION (EC1 PLUS RATED). SUITABLE OVER UNDERFLOOR HEATING (CHECK TEMPERATURE PROTOCOL). - WEBER FLOOR 4310: 3-30MM DEPTH. GOOD FOR THICKER POURS. WALKABLE 3-5 HOURS.
SLC APPLICATION REQUIREMENTS: 1. PRIMER: ALWAYS PRIME THE SUBSTRATE BEFORE SLC. ARDEX P 51 (FOR ABSORBENT SUBSTRATES), ARDEX P 82 (FOR NON-ABSORBENT — EXISTING TILES, TERRAZZO). PRIMER PREVENTS RAPID WATER ABSORPTION FROM THE SUBSTRATE (WHICH CAUSES CRACKING). 2. SEALING GAPS: FILL ALL GAPS IN THE SUBSTRATE (EXPANSION JOINTS, PIPE PENETRATIONS) WITH FOAM BACKER ROD AND SEALANT BEFORE POURING — SLC FINDS EVERY GAP AND FLOWS OUT. 3. MIX RATIO: FOLLOW MANUFACTURER INSTRUCTION PRECISELY. OVER-WATERING REDUCES STRENGTH AND CAUSES SURFACE DUSTING AFTER CURE. 4. POUR AND SPREAD WITHIN OPEN TIME: SLC HAS AN OPEN TIME OF 10-20 MINUTES — THE FULL FLOOR AREA SHOULD BE POURED AND SPREAD WITHIN THIS WINDOW.
SAND-CEMENT SCREED (FOR DEPTHS OVER 15MM OR LARGE AREAS): A TRADITIONAL SEMI-DRY SAND-CEMENT SCREED (1:3-1:4 CEMENT:SHARP SAND MIX, TAMPED DOWN) IS USED FOR DEPTHS OF 15-75MM. SLOWER DRYING (1MM PER DAY — A 50MM SCREED REQUIRES 50 DAYS DRYING BEFORE TILING) BUT PROVIDES THERMAL MASS FOR UNDERFLOOR HEATING SYSTEMS.
FLOWING SCREED (ANHYDRITE OR CALCIUM SULPHATE SCREED — HANSON CEMFLOOR, LAFARGE THERMIA): FLOWING SCREEDS ARE PUMPED AND SELF-LEVELLING — THEY ARE THE PREFERRED SCREED FOR UNDERFLOOR HEATING INSTALLATIONS: - HANSON CEMFLOOR 65MM DEPTH OVER UFH PIPES: THE STANDARD SPECIFICATION FOR LONDON EXTENSION KITCHEN-DINERS WITH NU-HEAT OR UPONOR UNDERFLOOR HEATING - SELF-LEVELS TO ±3MM FLATNESS (VERSUS ±5-8MM FOR HAND-SCREEDED SAND-CEMENT) - WALK-ON IN 24-48 HOURS; TILING AFTER 28 DAYS - ANHYDRITE SCREED MUST BE SEALED BEFORE TILING (ARDEX P 51 DILUTED 1:3 AS PRIMER — ANHYDRITE REACTS WITH CEMENT-BASED ADHESIVE IF UNSEALED) - DRYING TIME: 1MM PER DAY FOR THE FIRST 40MM; 0.5MM PER DAY ABOVE 40MM — A 65MM SCREED DRIES IN 90 DAYS NATURALLY (OR FORCE-DRIED WITH UFH AT LOW TEMPERATURE FROM DAY 7: 25°C FOR 7 DAYS, THEN 45°C FOR 7 DAYS)
Underfloor Heating and Moisture Checks
TWO IMPORTANT CONSIDERATIONS BEFORE AND AFTER FLOOR LEVELLING:
MOISTURE CHECK — CRITICAL BEFORE ANY FLOOR FINISH: RELATIVE HUMIDITY (RH) OF THE SUBSTRATE MUST BE BELOW: - 75% RH FOR MOST FLOORING TYPES (TILES, LVT, ENGINEERED TIMBER, CARPET) - 65% RH FOR SOLID TIMBER BOARDS - MEASURE WITH A CALIBRATED HYGROMETER (TRAMEX CME5, PROTIMETER SURVEYMASTER) — NOT JUST A SURFACE SCRATCH TEST
HOW LONG SHOULD SCREEDS DRY BEFORE CHECKING? - SAND-CEMENT SCREED: 1MM PER DAY (50MM = 50 DAYS MINIMUM) - ANHYDRITE FLOWING SCREED: 1MM/DAY TO 40MM, 0.5MM/DAY ABOVE 40MM — OR FORCE-DRY WITH UFH - IF MOISTURE IS STILL ELEVATED: SURFACE DPM (ARDEX MC RAPID MOISTURE CONTROL OR MAPEI PRIMER SN — TWO-COAT EPOXY-BASED MOISTURE BARRIER) CAN BE APPLIED TO ALLOW TILING BEFORE FULL DRYING (LOCKS IN RESIDUAL MOISTURE BELOW THE BARRIER)
UNDERFLOOR HEATING COMMISSIONING BEFORE TILING: FOR ANY FLOOR WITH ELECTRIC UFH OR HYDRONIC UFH BENEATH IT: - ELECTRIC UFH: CHECK ELECTRICAL RESISTANCE WITH MULTIMETER BEFORE POURING SCREED (WARMUP, NUHEAT, DCM-PRO ALL SUPPLY TEST CERTIFICATE) - HYDRONIC UFH (NU-HEAT LOOPSTRATE, UPONOR MLCP): PRESSURE-TEST PIPEWORK AT 6 BAR FOR 24 HOURS BEFORE SCREED POUR; MAINTAIN PRESSURE DURING SCREED POUR; RELEASE PRESSURE AFTER SCREED HAS CURED TO PREVENT PIPE MOVEMENT - DO NOT SWITCH ON UFH FOR THE FIRST 21 DAYS AFTER SCREED POUR (LET IT CURE NATURALLY FIRST)
COSTS FOR FLOOR LEVELLING IN LONDON (2025-2026): SELF-LEVELLING COMPOUND (ARDEX K 15 OR MAPEI ULTRAPLAN — SUPPLY AND APPLY, UP TO 10MM DEPTH, UP TO 20M²): £400-800 SAND-CEMENT SCREED (50MM, HAND-LAID, 20M²): £600-1,000 ANHYDRITE FLOWING SCREED (65MM WITH UFH, 20M², PUMPED): £800-1,400 HARDIE BACKER OVERLAY ON TIMBER FLOOR (18MM, SCREWED, INCLUDING PLYWOOD INTERMEDIATE IF REQUIRED, 20M²): £500-900 MOISTURE SURVEY AND DAMP READING REPORT: £150-300
Frequently Asked Questions
What is the best self-levelling compound for a London Victorian terrace floor?▼
Can I tile directly onto a suspended timber floor in a Victorian terrace?▼
What is a flowing screed and when should I use it?▼
How long does screed take to dry before tiling?▼
How much does floor levelling cost in London?▼
Important Note
This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. RCB Design & Build offers free initial consultations — book your free survey.