⭐ 9.96/10 Checkatrade · 114+ Reviews
📞 07359 872594
Windows & Glazing3 min read

uPVC Window Replacement in London Victorian Terraces: A-Rated Double Glazing and Conservation Areas

Window replacement is one of the most commonly undertaken home improvement projects in London — driven by the dual motivation of reducing heat loss through single-glazed or early double-glazed windows and improving acoustic performance (reducing traffic noise from London streets). In a London Victorian terrace where the original sash windows have already been replaced (as they have in the majority of Victorian terrace properties across London — typically by uPVC casement or sash-replacement windows fitted between the 1970s and 2000s), window replacement typically means replacing first-generation uPVC double-glazed windows with newer, more thermally efficient uPVC triple-glazed or timber double-glazed units — achieving both better thermal performance (lower U-value) and better acoustic performance (improved sound reduction). This guide covers the specification, planning, and cost of window replacement in a London Victorian terrace — with particular attention to the differences between conservation area and non-conservation area properties.

Key Takeaways

  • uPVC profile systems: Rehau Synego 86 (Rehau AG, Germany — largest uPVC profile manufacturer worldwide): 86mm system depth, 7 chambers, frame U-value 1.0 W/m²K, compatible with triple glazed to 44mm, fully galvanised steel reinforced; colours: white (standard), anthracite grey RAL 7016 (most popular non-white in London 2023-2025), cream, black, woodgrain foil; supply (standard casement 1200x1050mm from fabricator): £350-600; Deceuninck 2800 (Belgium, 88mm, 5 chambers, frame U-value 1.1 W/m²K — similar performance to Rehau at marginally lower cost); Veka Softline 82 (Germany, 82mm, 5 chambers, frame U-value 1.2 W/m²K, softer external radii profile); market: uPVC = ~75-80% of UK replacement window volume by units (2024)
  • Triple glazed IGU specification: 4/12/4/12/4 argon (36mm total) standard; centre-glass U-value ~0.6-0.7 W/m²K; low-E coating: Pilkington Energikare or Pilkington Optitherm S3 Plus on internal glass (reflects long-wave infrared back into room); warm-edge spacer: SwisspacerV (SwisspacerAG, Switzerland — edge-of-glass condensation resistance ~40% better than aluminium spacer); gas fill: argon (lambda 0.0178 W/mK at 50% concentration) or krypton (0.0093 W/mK, slimmer cavities); whole-window U-value (Rehau Synego 86 + 36mm triple DGU): ~0.8-1.0 W/m²K; WER (BFRC Window Energy Rating): combines U-value + solar heat gain (g-value) + air leakage (L-value); Part L 2021 minimum: C-rated WER OR whole-window ≤1.6 W/m²K; triple glazed Rehau Synego 86: A or A+ rated
  • Conservation area planning: Article 4 Direction (GPDO 2015 Article 4): local authority order removing PD right to replace windows — applies to most inner London conservation areas (Camden, Islington, Hackney, Wandsworth, Southwark, Lambeth etc.); without Article 4: window replacement = PD for houses (no planning permission required) under GPDO 2015 Schedule 2 Part 1 Class A; with Article 4: planning permission required — uPVC almost always refused (thick sightlines 65-80mm external vs original Victorian timber sash 15-25mm glazing bars, 40-50mm frame sightlines — visually incompatible); accepted alternatives: Accoya modified timber (acetylated radiata pine, 50-year above-ground durability, no biocides — Bereco, UK's leading Accoya sash window manufacturer, £1,500-3,000/window supply); Rationel ALDAS/Forma (Danish, Accoya clad, triple glazed, ~0.8 W/m²K); Velfac composite (timber-aluminium composite, slim profiles)
  • Part L 2021 and FENSA: all replacement windows are notifiable under Part L (thermal element renovation); FENSA (Fenestration Self-Assessment Scheme) or Certass registered installer: self-certifies without Building Control involvement, issues FENSA certificate registered with local authority; FENSA certificate: evidence of Part L compliance, required for conveyancing (solicitors check — absence causes delays on house sale); Part L 2021: whole-window U-value ≤1.6 W/m²K or BFRC C-rating minimum; uPVC double glazed (60-70mm, 24mm low-E argon): ~1.4-1.6 W/m²K — borderline; uPVC triple glazed (Rehau Synego 86, 36mm): ~0.8-1.1 W/m²K — comfortably compliant; single glazed replacement: ~4.8-5.5 W/m²K — non-compliant, unacceptable
  • Costs London 2025 (supply and fit, FENSA, incl. removal/fitting/seal/certificate): uPVC casement triple glazed (Rehau Synego 86, white, 1200x1050mm): total £500-850/window; uPVC vertical sliding sash replacement: £750-1,250/window; Accoya timber sash (Bereco, conservation area): £1,750-3,500/window; full terrace (8-10 windows): uPVC casement triple glazed £4,000-8,500; timber Accoya conservation area £14,000-35,000; bay window premium: 30-50% more than equivalent flat window (angled corner joins, bay roof, access); anthracite grey RAL 7016 colour surcharge: typically 5-15% on white price; woodgrain foil surcharge: similar; always verify: FENSA/Certass registration, Article 4 Direction status for your specific address, profile brand (Rehau/Veka/Deceuninck — not unbranded budget profiles)

uPVC Window Frame Systems: Rehau Synego 86, Deceuninck 2800, and Veka Softline

UPVC (UNPLASTICISED POLYVINYL CHLORIDE) WINDOW FRAMES ARE THE DOMINANT MATERIAL FOR REPLACEMENT WINDOWS IN THE UK RESIDENTIAL MARKET — ESTIMATED TO ACCOUNT FOR APPROXIMATELY 75-80% OF ALL REPLACEMENT WINDOW INSTALLATIONS IN THE UK (2024) BY UNIT VOLUME. UPVC WINDOWS ARE MANUFACTURED FROM EXTRUDED PROFILES — THE PROFILES ARE PRODUCED BY A SMALL NUMBER OF LARGE EUROPEAN EXTRUSION MANUFACTURERS (REHAU, VEKA, DECEUNINCK, KOMMERLING — ALL OF WHICH SUPPLY PROFILES TO THE NETWORK OF UK FABRICATORS WHO WELD THE PROFILES INTO FINISHED WINDOW UNITS).

REHAU SYNEGO 86 (REHAU AG — REHAU, GERMANY — THE PREMIUM PROFILE SYSTEM FROM REHAU — THE WORLD'S LARGEST UPVC WINDOW PROFILE MANUFACTURER): 86MM SYSTEM DEPTH (THE FRAME DEPTH FROM INSIDE TO OUTSIDE — 86MM IS THE CURRENT PREMIUM DEPTH FOR UK TRIPLE GLAZED WINDOWS — COMPARED WITH THE EARLIER 70MM AND 60MM SYSTEMS WHICH ACCOMMODATE ONLY DOUBLE GLAZED UNITS). 7-CHAMBER INTERNAL GEOMETRY (THE INTERNAL PROFILE IS DIVIDED INTO 7 SEPARATE AIR CHAMBERS — EACH ADDITIONAL CHAMBER ADDS THERMAL RESISTANCE AND STRUCTURAL RIGIDITY TO THE FRAME). FRAME U-VALUE: 1.0 W/M²K (SIGNIFICANTLY BETTER THAN OLDER 60-70MM UPVC PROFILES AT 1.4-1.8 W/M²K). COMPATIBLE WITH TRIPLE GLAZED UNITS UP TO 44MM DGU THICKNESS. FULLY REINFORCED WITH HOT-DIPPED GALVANISED STEEL INSERTS FOR STRUCTURAL INTEGRITY. COLOUR OPTIONS: WHITE (STANDARD), GREY (RAL 7016 ANTHRACITE — THE MOST POPULAR NON-WHITE COLOUR IN LONDON RESIDENTIAL REPLACEMENT WINDOWS 2023-2025), CREAM, BLACK, AND FOIL-LAMINATED FINISHES (WOODGRAIN FOIL — GOLDEN OAK, ROSEWOOD — LESS POPULAR IN LONDON THAN IN THE MIDLANDS AND NORTH). PRICE RANGE FOR A FABRICATED WINDOW UNIT (SUPPLY ONLY): TYPICAL CASEMENT WINDOW 1200MM WIDE X 1000MM HIGH (A COMMON LONDON VICTORIAN TERRACE FIRST-FLOOR WINDOW SIZE): SINGLE CASEMENT WITH SIDELIGHT — REHAU SYNEGO 86 — WHITE — TRIPLE GLAZED (ARGON — LOW-E — WARM-EDGE SPACER): APPROXIMATELY £350-600 (FROM FABRICATOR).

DECEUNINCK 2800 (DECEUNINCK NV — HOOGLEDE-GITS, BELGIUM — THE SECOND LARGEST UPVC PROFILE MANUFACTURER IN EUROPE): 88MM SYSTEM DEPTH. 5-CHAMBER MAIN FRAME + INTEGRATED DRAINAGE CHANNELS. FRAME U-VALUE: 1.1 W/M²K. WHITE OR RAL COLOUR FOIL. WIDELY USED BY BUDGET AND MID-RANGE UK WINDOW FABRICATORS. COMPARABLE PERFORMANCE TO REHAU SYNEGO 86 AT A MARGINALLY LOWER COST.

VEKA SOFTLINE 82 (VEKA AG — SENDENHORST, GERMANY — THE THIRD LARGEST UPVC EXTRUSION MANUFACTURER): 82MM DEPTH. 5 CHAMBERS. FRAME U-VALUE: 1.2 W/M²K. SOFTER EXTERNAL SIGHTLINE RADII (THE EXTERNAL CORNERS ARE LESS SQUARE THAN REHAU OR DECEUNINCK — SOME SPECIFIERS CONSIDER THE SOFTER PROFILE MORE COMPATIBLE WITH THE CURVED ARCHITRAVES OF VICTORIAN TERRACE WINDOWS). PRICE: SIMILAR TO DECEUNINCK 2800.

Glazing Specification: Triple Glazed Units and WER Ratings

THE GLAZING UNIT (THE INSULATING GLASS UNIT — IGU — COMPRISING THE GLASS PANES, SPACER BAR, AND GAS FILL) IS THE LARGEST CONTRIBUTOR TO THE WHOLE-WINDOW U-VALUE — THE FRAME ACCOUNTS FOR APPROXIMATELY 20-30% OF THE TOTAL WINDOW AREA AND THE GLAZED UNIT THE REMAINING 70-80% IN A TYPICAL WINDOW.

TRIPLE GLAZED IGU (THE CURRENT STANDARD FOR PREMIUM REPLACEMENT WINDOWS IN THE UK MARKET): THREE GLASS PANES (TYPICALLY 4MM TOUGHENED OUTER + 12MM GAS CAVITY + 4MM FLOAT + 12MM GAS CAVITY + 4MM INNER GLASS = 36MM TOTAL UNIT WIDTH — THE STANDARD TRIPLE GLAZED UNIT). GAS FILL: ARGON (THE MOST COMMON — CONDUCTIVITY APPROXIMATELY 0.0178 W/MK AT 50% ARGON CONCENTRATION — STANDARD IN MOST PREMIUM UK TRIPLE GLAZED UNITS) OR KRYPTON (HIGHER THERMAL PERFORMANCE — USED IN SLIMMER UNITS WHERE THE CAVITY SPACE IS LIMITED — CONDUCTIVITY APPROXIMATELY 0.0093 W/MK). LOW-E COATING: ALL PREMIUM DOUBLE AND TRIPLE GLAZED UNITS INCLUDE A LOW-EMISSIVITY (LOW-E) COATING ON THE INTERNAL GLASS SURFACE — PILKINGTON ENERGIKARE OR PILKINGTON OPTITHERM S3 PLUS (THE TWO MOST WIDELY USED LOW-E COATINGS IN UK REPLACEMENT WINDOWS) — THE COATING REFLECTS LONG-WAVE INFRARED RADIATION (HEAT) BACK INTO THE ROOM — REDUCING RADIANT HEAT LOSS THROUGH THE GLASS. WARM-EDGE SPACER (THE THERMALLY BROKEN SPACER BAR BETWEEN GLASS PANES — REPLACING THE TRADITIONAL ALUMINIUM SPACER WITH A POLYMER OR FOAM SPACER THAT DOES NOT CONDUCT HEAT BETWEEN THE GLASS PANES AT THE EDGE OF THE UNIT — REDUCING THE LINEAR THERMAL TRANSMITTANCE PSIS — AT THE PERIMETER OF THE GLASS): SWISSPACER V (THE PREMIUM WARM-EDGE SPACER — SWISSPACER AG, SWITZERLAND — EDGE-OF-GLASS CONDENSATION RESISTANCE APPROXIMATELY 40% BETTER THAN ALUMINIUM SPACER — USED BY ALL PREMIUM UK WINDOW FABRICATORS). TYPICAL CENTRE-OF-GLASS U-VALUE FOR A TRIPLE GLAZED 4/12/4/12/4 ARGON LOW-E UNIT: APPROXIMATELY 0.6-0.7 W/M²K. WHOLE-WINDOW U-VALUE (INCLUDING FRAME — REHAU SYNEGO 86 FRAME): APPROXIMATELY 0.8-1.0 W/M²K.

WINDOW ENERGY RATING (WER — THE BFRC WINDOW ENERGY RATING — THE BRITISH FENESTRATION RATING COUNCIL LABEL DISPLAYED ON REPLACEMENT WINDOWS IN THE UK — RATING A++ TO E): THE WER COMBINES THREE FACTORS: HEAT LOSS THROUGH THE WINDOW (U-VALUE), SOLAR HEAT GAIN (G-VALUE — HOW MUCH SOLAR ENERGY PASSES THROUGH THE GLAZING INTO THE ROOM), AND AIR LEAKAGE (L-VALUE). FOR A REPLACEMENT WINDOW TO COMPLY WITH PART L 2021 BUILDING REGULATIONS IN AN EXISTING DWELLING: THE WHOLE-WINDOW U-VALUE MUST BE A MAXIMUM OF 1.6 W/M²K (OR THE WINDOW MUST ACHIEVE A MINIMUM WER OF C-RATED UNDER THE BFRC SCHEME). TRIPLE GLAZED WINDOWS (REHAU SYNEGO 86 + 36MM TRIPLE GLAZED ARGON LOW-E UNIT): TYPICALLY RATED A OR A+ ON THE WER SCALE — EXCEEDING THE PART L 2021 MINIMUM. DOUBLE GLAZED WINDOWS (60-70MM UPVC FRAME + 24MM DOUBLE GLAZED LOW-E ARGON UNIT): TYPICALLY RATED B OR C — BORDERLINE COMPLIANCE WITH PART L 2021 1.6 W/M²K.

Conservation Area Planning: Article 4 and Timber Alternatives

WINDOW REPLACEMENT IN A LONDON CONSERVATION AREA IS ONE OF THE MOST COMMON PLANNING ISSUES FACED BY VICTORIAN TERRACE HOMEOWNERS — BECAUSE THE ARTICLE 4 DIRECTION (A LOCAL AUTHORITY ORDER UNDER ARTICLE 4 OF THE TOWN AND COUNTRY PLANNING (GENERAL PERMITTED DEVELOPMENT) ORDER 2015) IN MANY LONDON CONSERVATION AREAS REMOVES THE PERMITTED DEVELOPMENT RIGHT TO REPLACE WINDOWS WITHOUT PLANNING PERMISSION.

ARTICLE 4 DIRECTIONS AND WINDOW REPLACEMENT IN CONSERVATION AREAS: WITHOUT AN ARTICLE 4 DIRECTION: WINDOW REPLACEMENT IS PERMITTED DEVELOPMENT (NO PLANNING PERMISSION REQUIRED) FOR HOUSES IN ENGLAND — UNDER SCHEDULE 2 PART 1 CLASS A OF THE GPDO 2015. WITH AN ARTICLE 4 DIRECTION (WHICH APPLIES TO MOST CONSERVATION AREAS IN INNER LONDON BOROUGHS — INCLUDING CAMDEN, ISLINGTON, HACKNEY, WANDSWORTH, SOUTHWARK, AND LAMBETH): WINDOW REPLACEMENT REQUIRES PLANNING PERMISSION — AND THE LOCAL AUTHORITY WILL TYPICALLY REQUIRE THAT REPLACEMENT WINDOWS MATCH THE ORIGINAL WINDOW STYLE (TYPICALLY VERTICAL SLIDING SASH STYLE FOR A VICTORIAN TERRACE) AND BE IN A MATERIAL THAT IS COMPATIBLE WITH THE CONSERVATION AREA CHARACTER — TYPICALLY TIMBER (NOT UPVC). UPVC IN CONSERVATION AREAS: UPVC WINDOWS ARE ALMOST ALWAYS REFUSED IN A CONSERVATION AREA WITH AN ARTICLE 4 DIRECTION WHERE THE ORIGINAL STYLE WAS TIMBER SASH — THE THICK FRAME PROFILES OF UPVC (TYPICALLY 65-80MM EXTERNAL SIGHTLINES) ARE VISUALLY INCOMPATIBLE WITH THE SLIM PROFILES OF ORIGINAL TIMBER SASH WINDOWS (TYPICALLY 15-25MM GLAZING BAR WIDTH AND 40-50MM FRAME SIGHT LINES).

TIMBER ALTERNATIVES ACCEPTED IN CONSERVATION AREAS (WHEN PLANNING PERMISSION FOR WINDOW REPLACEMENT IS REQUIRED IN A CONSERVATION AREA): ACCOYA (ACETYLATED RADIATA PINE — ACCOYA UK, HERTFORD — THE MOST DIMENSIONALLY STABLE MODIFIED TIMBER WINDOW FRAME MATERIAL AVAILABLE — MODIFIED BY ACETYLATION TO RESIST MOISTURE, ROT, AND DECAY — RATED FOR 50-YEAR ABOVE-GROUND DURABILITY WITHOUT BIOCIDES — THE PREFERRED MATERIAL FOR CONSERVATION AREA REPLACEMENT TIMBER SASH WINDOWS): AVAILABLE FROM BERECO (THE LEADING UK TIMBER SASH WINDOW MANUFACTURER — ABERDEENSHIRE — ACCOYA REPLACEMENT SASH WINDOW UNITS WITH SLIM DOUBLE GLAZED UNITS — BESPOKE AND STANDARD SIZES). PRICE: £1,500-3,000 PER WINDOW (SUPPLY ONLY — SIGNIFICANTLY MORE THAN UPVC). RATIONEL (DANISH — ALDAS AND FORMA RANGE — ACCOYA CLADDING ON PINE CORE — TRIPLE GLAZED — AVAILABLE FROM RATIONEL UK AND APPROVED RETAILERS): PREMIUM TIMBER WINDOW WITH EXCELLENT THERMAL PERFORMANCE (U-VALUE ~0.8 W/M²K WHOLE WINDOW — TRIPLE GLAZED). ALTERNATIVE FOR NON-CONSERVATION AREAS: COMPOSITE WINDOWS (ALUMINIUM-CLAD TIMBER — INTERNORM, VELFAC, RATIONEL VARIO — TIMBER INNER FACE + ALUMINIUM EXTERNAL CLADDING) PROVIDE THE LOOK OF TIMBER INTERNALLY AND REQUIRE MINIMAL EXTERNAL MAINTENANCE — POPULAR IN LONDON PREMIUM RENOVATION MARKET.

Window Installation: Fitting, Reveals, and Building Regulations

WINDOW REPLACEMENT IN A LONDON VICTORIAN TERRACE INVOLVES THREE MAIN INSTALLATION STAGES: REMOVAL OF THE EXISTING WINDOW, PREPARATION OF THE REVEAL (THE BRICK SURROUND OF THE WINDOW OPENING), AND FITTING OF THE NEW WINDOW UNIT.

REMOVAL OF THE EXISTING WINDOW: IN A VICTORIAN TERRACE WHERE THE EXISTING WINDOW IS A LATER UPVC REPLACEMENT (FITTED IN A STANDARD BRICK REVEAL WITHOUT SUBFRAME): THE UPVC WINDOW IS TYPICALLY REMOVED BY CUTTING THE FIXINGS (FRAME FIXINGS INTO THE REVEAL BRICKWORK — TYPICALLY RAWLBOLTS OR FRAME FIXINGS AT 600MM CENTRES THROUGH THE UPVC FRAME FLANGE INTO THE BRICK REVEAL) AND CUTTING THE MASTIC SEAL AT THE PERIMETER. THE EXISTING WINDOW IS THEN LIFTED OUT IN SASHES (REMOVE GLAZED SASHES FIRST TO REDUCE WEIGHT) AND THE FRAME PULLED CLEAR. IN A VICTORIAN TERRACE WHERE THE ORIGINAL TIMBER BOX FRAME IS STILL IN PLACE (EVEN IF THE SASHES HAVE BEEN REPLACED): THE ORIGINAL TIMBER BOX FRAME (THE CASED BOX FRAME WITH SASH WEIGHTS BEHIND) IS SUBSTANTIALLY DEEPER THAN A STANDARD UPVC REVEAL FRAME — REMOVING THE BOX FRAME REVEALS THE FULL MASONRY REVEAL BEHIND — THE NEW WINDOW FITS INTO THIS MASONRY REVEAL DIRECTLY (WITHOUT SUBFRAME). REVEAL PREPARATION: THE MASONRY REVEAL (BRICK JAMBS, HEAD, AND SILL) SHOULD BE CHECKED FOR: SOUND MORTAR JOINTS (REPOINT IN LIME OR CEMENT:LIME 4:1:3 MIX WHERE JOINTS ARE OPEN OR CRUMBLING); LEVEL SILL (THE STONE OR BRICK SILL ONTO WHICH THE WINDOW SITS SHOULD BE LEVEL AND UNDAMAGED — AN UNLEVEL SILL MUST BE BUILT UP WITH MORTAR BEFORE THE WINDOW IS FIXED); EXISTING LINTEL (THE LINTEL OVER THE WINDOW OPENING — IN A VICTORIAN TERRACE THIS IS TYPICALLY EITHER A BRICK JACK ARCH OR A CONCEALED STEEL LINTEL — MUST BE INTACT AND UNCRACKED BEFORE A NEW WINDOW IS FITTED).

FITTING THE NEW WINDOW: THE NEW WINDOW UNIT IS PLACED INTO THE REVEAL — PACKED OFF THE SILL WITH PLASTIC PACKERS TO ACHIEVE THE CORRECT SILL CLEARANCE (MINIMUM 10MM AIR GAP BELOW THE FRAME FOR VENTILATION AND DRAINAGE) — PLUMBED VERTICALLY AND LEVELLED — THEN FIXED THROUGH THE FRAME FLANGE INTO THE BRICK REVEAL WITH STAINLESS STEEL FRAME FIXINGS (MINIMUM 2 PER FRAME SIDE — AT 600MM MAXIMUM CENTRES). THE PERIMETER GAP BETWEEN THE WINDOW FRAME AND THE BRICK REVEAL IS SEALED WITH: EXPANDING FOAM (LOW-EXPANSION WINDOW AND DOOR FOAM — SOUDAL OR HILTI CF 812 — APPLIED AROUND THE FULL PERIMETER — ALLOWED TO CURE — TRIMMED FLUSH) AND EXTERNAL MASTIC SEALANT (SILICONE OR POLYURETHANE — APPLIED OVER THE CURED FOAM AT THE EXTERNAL FACE — TOOLED SMOOTH — ENSURES A CONTINUOUS WATERPROOF SEAL AT THE WEATHER FACE).

Part L 2021 Compliance and Building Regulations for Window Replacement

WINDOW REPLACEMENT IN AN EXISTING DWELLING (NOT A NEW BUILD OR EXTENSION) IS BUILDING REGULATIONS-NOTIFIABLE UNDER PART L (CONSERVATION OF FUEL AND POWER) IN THE FOLLOWING CIRCUMSTANCES.

WHEN IS WINDOW REPLACEMENT NOTIFIABLE: ALL WINDOW REPLACEMENTS (REMOVING AN EXISTING WINDOW AND FITTING A NEW UNIT IN THE SAME OPENING — REPLACEMENT WINDOWS) ARE NOTIFIABLE UNDER PART L BECAUSE THEY CONSTITUTE A RENOVATION TO A THERMAL ELEMENT (THE WINDOW IS A THERMAL ELEMENT OF THE BUILDING ENVELOPE). THE INSTALLER MUST EITHER: BE REGISTERED UNDER A COMPETENT PERSON SCHEME (FENSA — FENESTRATION SELF-ASSESSMENT SCHEME — OR CERTASS — THE TWO MAIN COMPETENT PERSON SCHEMES FOR WINDOW AND DOOR INSTALLERS IN ENGLAND — BOTH ALLOW REGISTERED INSTALLERS TO SELF-CERTIFY THEIR OWN WINDOW INSTALLATIONS WITHOUT BUILDING CONTROL INVOLVEMENT), OR NOTIFY BUILDING CONTROL BEFORE INSTALLATION AND OBTAIN A COMPLETION CERTIFICATE AFTER INSTALLATION (THE BUILDING CONTROL ROUTE — MORE EXPENSIVE AND SLOWER — NOT USED IN PRACTICE FOR STANDARD REPLACEMENT WINDOWS). VIRTUALLY ALL UK REPLACEMENT WINDOW INSTALLERS ARE FENSA OR CERTASS REGISTERED — THIS IS A STANDARD INDUSTRY REQUIREMENT. THE INSTALLER ISSUES A FENSA CERTIFICATE (OR CERTASS CERTIFICATE) AFTER INSTALLATION — THE CERTIFICATE IS REGISTERED WITH THE LOCAL AUTHORITY AND CAN BE SEARCHED BY SOLICITORS AS PART OF A HOUSE PURCHASE (FENSA CERTIFICATES ARE THE PRIMARY EVIDENCE THAT A REPLACEMENT WINDOW COMPLIES WITH BUILDING REGULATIONS — THE ABSENCE OF A CERTIFICATE FOR REPLACEMENT WINDOWS VISIBLE ON A HOUSE CAN CAUSE ISSUES ON CONVEYANCING).

PART L 2021 U-VALUE REQUIREMENT FOR REPLACEMENT WINDOWS: MAXIMUM WHOLE-WINDOW U-VALUE 1.6 W/M²K (OR MINIMUM BFRC WER OF C-RATING). IN PRACTICE: ALL CURRENT UPVC DOUBLE GLAZED WINDOWS (WITH LOW-E COATING AND ARGON FILL IN THE CAVITY) ACHIEVE APPROXIMATELY 1.4-1.6 W/M²K WHOLE-WINDOW U-VALUE — BORDERLINE COMPLIANCE. UPVC TRIPLE GLAZED WINDOWS (REHAU SYNEGO 86 OR EQUIVALENT): 0.8-1.1 W/M²K — WELL WITHIN PART L 2021. SINGLE GLAZED REPLACEMENT: WOULD NOT COMPLY WITH PART L 2021 AND SHOULD NOT BE SPECIFIED FOR NOTIFIABLE REPLACEMENT WINDOW WORK.

Replacement Window Costs in London

REPLACEMENT WINDOW COSTS IN LONDON (2025 — SUPPLY AND FIT — FENSA-REGISTERED INSTALLER — INCLUDING REMOVAL OF EXISTING WINDOW, FITTING OF NEW WINDOW, EXPANDING FOAM, MASTIC SEAL, AND FENSA CERTIFICATE REGISTRATION).

UPVC CASEMENT WINDOW (REHAU SYNEGO 86 OR EQUIVALENT — TRIPLE GLAZED — WHITE — STANDARD CASEMENT OPENING WITH FIXED SIDELIGHT — APPROXIMATELY 1200MM WIDE X 1050MM HIGH — THE STANDARD FIRST-FLOOR WINDOW SIZE IN A LONDON VICTORIAN TERRACE): SUPPLY: £350-600 PER WINDOW. INSTALLATION LABOUR: £150-250 PER WINDOW. TOTAL SUPPLY AND FIT: £500-850 PER WINDOW.

UPVC SASH REPLACEMENT WINDOW (A UPVC WINDOW DESIGNED TO REPLICATE THE APPEARANCE OF A TIMBER SASH WINDOW — VERTICAL SLIDING SASH MOVEMENT — DOUBLE HUNG — USED IN CONSERVATION AREAS WHERE UPVC IS PERMITTED OR FOR PROPERTIES OUTSIDE CONSERVATION AREAS WHERE THE OWNER WANTS A SASH APPEARANCE WITHOUT TIMBER MAINTENANCE): SUPPLY: £600-1,000 PER WINDOW (MORE EXPENSIVE THAN STANDARD CASEMENT — SASH-REPLACEMENT UPVC HAS A MORE COMPLEX PROFILE AND MECHANISM). TOTAL SUPPLY AND FIT: £750-1,250 PER WINDOW.

TIMBER SASH REPLACEMENT (ACCOYA — BERECO — CONSERVATION AREA): SUPPLY: £1,500-3,000 PER WINDOW. INSTALLATION: £250-500 PER WINDOW. TOTAL: £1,750-3,500 PER WINDOW.

FULL VICTORIAN TERRACE WINDOW REPLACEMENT (ALL WINDOWS — TYPICAL LONDON VICTORIAN TWO-STOREY TERRACE — 8-10 WINDOWS — UPVC CASEMENT TRIPLE GLAZED — WHITE): TOTAL SUPPLY AND FIT (INCLUDING BAY WINDOW IF APPLICABLE — BAY WINDOW MORE EXPENSIVE DUE TO ANGLED FRAME JOINS AND ACCESS REQUIREMENTS): £4,000-8,500. FOR TIMBER ACCOYA (CONSERVATION AREA — SAME QUANTITY): £14,000-35,000.

BAY WINDOW PREMIUM: IN A LONDON VICTORIAN TERRACE WITH A BAY WINDOW AT GROUND LEVEL (A VERY COMMON FEATURE — THREE-SIDED BAY AT 45° OR BOX BAY AT 90°), THE BAY WINDOW IS TYPICALLY 30-50% MORE EXPENSIVE THAN A FLAT WINDOW OF THE SAME SIZE — DUE TO THE ANGLED JOINERY AT THE BAY CORNERS, THE REQUIREMENT FOR A LEAD OR FELT-COVERED BAY ROOF, AND THE ADDITIONAL SCAFFOLDING OR ACCESS EQUIPMENT REQUIRED TO WORK ON THE EXTERNAL FACE.

Frequently Asked Questions

Can I replace my windows with uPVC in a London conservation area?
In most London conservation areas: No — or at least not without planning permission, which is typically refused for uPVC. Most London conservation areas (particularly in inner London boroughs such as Camden, Islington, Hackney, Wandsworth, Southwark, and Lambeth) have Article 4 Directions that remove the Permitted Development right to replace windows, meaning planning permission is required. Conservation officers almost always refuse uPVC in conservation areas where the original style was timber sash — because uPVC profiles have visually incompatible thick sightlines (65-80mm external visible widths) compared with original Victorian timber sash profiles (15-25mm glazing bars, 40-50mm frame sightlines). The accepted alternatives for conservation area window replacement in London: Accoya modified timber sash windows (Bereco, Bespoke Sash Window Workshop — Accoya is acetylated radiata pine with 50-year above-ground durability rating, accepted by most London conservation officers); Rationel ALDAS or Velfac composite (timber-aluminium composite, slim profiles, accepted in many conservation areas); Slim double-glazed units in restored original sash frames. Check your specific local authority's conservation area guidance before applying.
What is the best uPVC window profile for a London Victorian terrace?
For a non-conservation area London Victorian terrace where uPVC replacement windows are permitted: Rehau Synego 86 (86mm depth, 7-chamber profile, frame U-value 1.0 W/m²K, compatible with triple glazed units up to 44mm thick, frame U-value significantly better than older 60-70mm profiles at 1.4-1.8 W/m²K) is the top specification for maximum thermal performance. With a 36mm triple glazed unit (4/12/4/12/4, argon, Pilkington Energikare or Optitherm S3 Plus low-E, SwisspacerV warm-edge) the whole-window U-value is approximately 0.8-1.0 W/m²K — well above the Part L 2021 requirement of 1.6 W/m²K and achieving an A or A+ WER rating. Alternatives: Deceuninck 2800 (88mm, 5-chamber, frame U-value 1.1 W/m²K, slightly lower cost) and Veka Softline 82 (82mm, 5-chamber, softer external radii profile some consider more compatible with Victorian architecture, frame U-value 1.2 W/m²K). Most reputable UK window fabricators use one of these three systems. Specify white or anthracite grey RAL 7016 for London; avoid woodgrain foil which looks incongruous on a Victorian terrace.
Do I need a FENSA certificate for window replacement in London?
Yes. All replacement window installations in an existing dwelling in England are notifiable under Part L of the Building Regulations (thermal element renovation). The simplest compliance route is using a FENSA-registered (Fenestration Self-Assessment Scheme) or Certass-registered installer — virtually all reputable UK window companies are FENSA or Certass registered. A FENSA-registered installer can self-certify the installation complies with Building Regulations without involving Building Control — they issue a FENSA certificate which is registered with the local authority. This certificate is important for conveyancing: when you sell the property, solicitors check for FENSA certificates for any replacement windows visible in the sale. Absence of a FENSA certificate (or alternative Building Control Completion Certificate) for replacement windows can delay or complicate a house sale. Always request the FENSA certificate from your installer after window replacement and store it with your property documents.
What Part L 2021 U-value do replacement windows need to meet?
Under Approved Document L 2021 (Conservation of Fuel and Power — Volume 1: Dwellings), replacement windows in an existing dwelling must achieve a whole-window U-value of maximum 1.6 W/m²K (or a minimum BFRC Window Energy Rating of C). In practice: uPVC double-glazed windows (60-70mm profile, 24mm low-E argon DGU): whole-window U-value approximately 1.4-1.6 W/m²K — borderline compliance with Part L 2021; uPVC triple-glazed windows (Rehau Synego 86 or similar 82-88mm profile, 36mm triple-glazed argon low-E unit): approximately 0.8-1.1 W/m²K — comfortably compliant, rated A or A+ on WER scale; Accoya timber triple-glazed (Rationel ALDAS): approximately 0.8 W/m²K whole-window; single glazed windows: approximately 4.8-5.5 W/m²K — massively non-compliant, not acceptable as a replacement window under Part L 2021. Specify triple glazed for all new replacement window work to ensure compliance and future-proof the thermal performance.
How much does window replacement cost in London?
Window replacement costs in London (2025, supply and fit, FENSA-registered installer, including removal, fitting, seal, and certificate): uPVC casement triple glazed (Rehau Synego 86 or equivalent, white, standard casement 1200x1050mm): supply £350-600, installation £150-250, total £500-850 per window; uPVC vertical sliding sash replacement: total £750-1,250 per window; Accoya timber sash replacement (Bereco, conservation area): supply £1,500-3,000, total £1,750-3,500 per window; full Victorian terrace (8-10 windows, uPVC casement triple glazed): £4,000-8,500 total including bay window premium if applicable; full terrace (timber Accoya, conservation area): £14,000-35,000. Bay window premium: 30-50% more expensive per window than equivalent flat window (angled corner joins, bay roof, access equipment). Always request FENSA certificate, check if Article 4 Direction applies to your conservation area before ordering, and verify the installer is using a recognised profile system (Rehau, Veka, Deceuninck) not a budget system.

Important Note

This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. RCB Design & Build offers free initial consultations — book your free survey.

Ready to Discuss Your Project?

Free site survey. No obligation. Covering all Greater London & M25.

📞 Call now💬 WhatsAppFree Quote