ROOF TERRACES ARE ONE OF THE FEW DOMESTIC PROJECTS WHERE PLANNING PERMISSION IS ALMOST ALWAYS REQUIRED IN LONDON — THEY ARE NOT PERMITTED DEVELOPMENT.
WHY PLANNING PERMISSION IS REQUIRED: A ROOF TERRACE FUNDAMENTALLY CHANGES THE USE OF A ROOF FROM AN UNOCCUPIED STRUCTURE TO AN OCCUPIED AMENITY SPACE. PLANNING POLICIES CONSIDER: LOSS OF PRIVACY TO NEIGHBOURS (OVERLOOKING NEIGHBOUR GARDENS AND ROOMS FROM AN ELEVATED POSITION); NOISE (PARTIES, SOCIAL GATHERINGS AT HEIGHT); CHANGE IN CHARACTER (RAILING AND LIGHTING AT ROOF LEVEL VISIBLE FROM THE STREET); AND STRUCTURAL ALTERATIONS. GPDO 2015 DOES NOT PROVIDE PERMITTED DEVELOPMENT RIGHTS FOR ROOF TERRACES ON THE PRINCIPAL OR REAR ELEVATIONS OF DWELLINGS.
PLANNING APPLICATION CONSIDERATIONS: A HOUSEHOLDER PLANNING APPLICATION IS REQUIRED. THE APPLICATION SHOULD INCLUDE: - EXISTING AND PROPOSED FLOOR PLANS (SHOWING THE NEW TERRACE LEVEL, BALUSTRADE POSITIONS, ACCESS STAIR OR HATCH) - ELEVATIONS AND SECTIONS (SHOWING BALUSTRADE HEIGHT AND MATERIAL, EFFECT ON SKYLINE) - VISIBILITY ANALYSIS (CONFIRMING OVERLOOKING IMPACT ON NEIGHBOURS) - MATERIALS SPECIFICATION (GLASS VS STEEL VS TIMBER BALUSTRADE; DECK FINISH)
CONSERVATION AREAS AND LISTED BUILDINGS: IN CONSERVATION AREAS (WHICH COVER APPROXIMATELY 35-40% OF LONDON RESIDENTIAL STOCK), PLANNING APPLICATIONS FOR ROOF TERRACES ARE SCRUTINISED CAREFULLY. OBJECTIONS TYPICALLY FOCUS ON: VISIBILITY OF BALUSTRADE ABOVE PARAPET LINE; LOSS OF PRIVACY TO NEIGHBOURS; AND NOISE. MANY CONSERVATION OFFICERS PREFER INSET TERRACES (BELOW THE PARAPET LINE, NOT VISIBLE FROM THE STREET) OVER TERRACES WITH VISIBLE BALUSTRADES ABOVE RIDGE OR PARAPET LEVEL.
LIKELY PLANNING OUTCOMES: INSET TERRACE (SUNKEN BELOW EXISTING PARAPET LEVEL — PARAPET HEIGHT UNCHANGED): GOOD CHANCE OF APPROVAL IN MOST LONDON BOROUGHS. TERRACE WITH GLASS BALUSTRADE ABOVE PARAPET: ACCEPTABLE IN MANY BOROUGHS IF THE GLASS IS CLEAR (NOT OPAQUE) AND THE DESIGN IS CONSIDERED; MAY BE REFUSED IN CONSERVATION AREAS. TERRACE WITH SOLID OR TIMBER BALUSTRADE ABOVE PARAPET: FREQUENTLY REFUSED WHERE VISIBLE FROM THE STREET OR NEIGHBOURING GARDENS. PRE-APPLICATION ADVICE FROM THE BOROUGH PLANNING AUTHORITY IS STRONGLY RECOMMENDED BEFORE DETAILED DESIGN.
Structural Requirements for Accessible Roof Terraces
A ROOF DESIGNED FOR NON-ACCESSIBLE USE (MAINTENANCE ONLY) HAS VERY DIFFERENT STRUCTURAL REQUIREMENTS FROM AN ACCESSIBLE ROOF TERRACE — THIS IS A CRITICAL DISTINCTION.
LOADING REQUIREMENTS: EUROCODE 1 (BS EN 1991-1-1) SPECIFIES IMPOSED LOADING FOR ACCESSIBLE ROOFS: - NON-ACCESSIBLE ROOF (MAINTENANCE ONLY): 0.6 KN/M² IMPOSED LOAD - ACCESSIBLE ROOF TERRACE (DOMESTIC USE): CATEGORY A1 — 1.5 KN/M² IMPOSED LOAD (MINIMUM) - ACCESSIBLE ROOF TERRACE WITH HEAVY PLANTING/LANDSCAPING: MAY INCREASE TO 3.0-5.0 KN/M² DEPENDING ON SOIL/GROWING MEDIUM DEPTH
FOR A TYPICAL LONDON REAR EXTENSION FLAT ROOF BEING CONVERTED TO A TERRACE, THE STRUCTURAL IMPLICATIONS ARE: - EXISTING ROOF JOISTS (TYPICALLY 150X50MM OR 175X50MM C16 JOISTS AT 400MM CENTRES) DESIGNED FOR 0.6 KN/M² MAY BE INADEQUATE FOR 1.5 KN/M² — A STRUCTURAL ENGINEER MUST ASSESS AND SPECIFY ANY REQUIRED UPGRADES - COMMON UPGRADING SOLUTIONS: SISTER JOISTS (SECOND JOIST BOLTED ALONGSIDE EXISTING); POSI-JOISTS (ENGINEERED FLOOR JOIST — MUCH HIGHER CAPACITY); REPLACE JOISTS WITH NEW DEEPER SECTION; OR INSTALL ADDITIONAL STRUCTURAL STEEL BEAM BELOW
BALUSTRADE STRUCTURAL LOADING: BALUSTRADES ON A ROOF TERRACE MUST RESIST HORIZONTAL LINE LOAD OF 0.74 KN/M (MINIMUM, AS PER BS EN 1991-1-1 AND BS 6180) — THIS IS THE EQUIVALENT OF CROWD PUSH LOAD. THE BALUSTRADE POST FIXINGS MUST TRANSFER THIS LOAD TO THE STRUCTURAL DECK, NOT TO THE WATERPROOFING MEMBRANE (A COMMON FAILURE MODE). BALUSTRADE POSTS MUST BE: CORE-DRILLED THROUGH THE DECK INTO THE STRUCTURAL JOIST; OR MOUNTED ON PROPRIETARY BASE PLATES THROUGH THE STRUCTURE; WITH SEALANT AND FLASHING DETAIL AROUND THE PENETRATION TO MAINTAIN WATERPROOFING INTEGRITY.
STRUCTURAL ENGINEER APPOINTMENT: A STRUCTURAL ENGINEER MUST ASSESS THE EXISTING STRUCTURE AND SPECIFY ANY REQUIRED UPGRADES. PROVIDE THE ENGINEER WITH: EXISTING JOIST SIZES AND SPACINGS (MEASURE CAREFULLY OR CORE DRILL TO INSPECT); THE PROPOSED TERRACE SIZE; AND PROPOSED LOADINGS (INCLUDING DECKING MATERIAL, PLANTERS, HOT TUB IF APPLICABLE).
Waterproofing and Drainage for Accessible Roofs
AN ACCESSIBLE ROOF TERRACE HAS HIGHER WATERPROOFING DEMANDS THAN A STANDARD FLAT ROOF — FOOT TRAFFIC, DROPPED ITEMS, FURNITURE LEGS, AND BALUSTRADE POST PENETRATIONS ALL CREATE ADDITIONAL RISK OF MEMBRANE DAMAGE.
RECOMMENDED WATERPROOFING SYSTEMS FOR ACCESSIBLE TERRACES: SINGLE-PLY PVC (SIKA SARNAFIL G410-15EL 1.5MM OR FIRESTONE ULTRAPLY TPO 1.5MM): THE PREFERRED SYSTEM FOR MOST LONDON ACCESSIBLE TERRACES. MECHANICALLY FIXED WITH HOT-AIR WELDED OVERLAPS. DURABLE; CRACK-BRIDGING; UV-STABLE. FOR ACCESSIBLE TERRACES, CHOOSE THE 1.5MM THICKNESS MINIMUM (NOT 1.2MM). COMPATIBLE WITH PEDESTAL-MOUNTED DECKING (DECKING ON ADJUSTABLE PEDESTALS PROTECTS THE MEMBRANE FROM FOOT TRAFFIC AND UV).
LIQUID APPLIED WATERPROOFING (TREMCO VULKEM 350, SIKA LIQUID PLASTICS DECOTHANE ULTRA 25): COLD-APPLIED LIQUID SYSTEMS THAT FORM A SEAMLESS MEMBRANE — GOOD FOR COMPLEX SHAPES AND DETAILS. USED OVER PLYWOOD DECKS. MUST BE PROTECTED FROM FOOT TRAFFIC BY DECKING BOARDS OR TILES ON PEDESTALS.
EPDM (FIRESTONE RUBBERCOVER 1.52MM): COLD-BONDED EPDM — LOWER COST; GOOD FOR SIMPLE SHAPES; NOT RECOMMENDED FOR HIGH-PEDESTRIAN TERRACES WITHOUT PEDESTAL PROTECTION.
DRAINAGE DESIGN: ACCESSIBLE TERRACES MUST DRAIN ADEQUATELY TO PREVENT PONDING (POOLED WATER DEGRADES MEMBRANE AND CREATES SLIP HAZARD). MINIMUM: FALLS OF 1:80 (1.25%) TO ROOF DRAINAGE OUTLETS. ACO KLICK TOP FLAT ROOF DRAIN (STAINLESS STEEL GRATING, 75-110MM DIAMETER OUTLET) OR SITA SIPHONIC ROOF OUTLET FOR LARGER TERRACES. SECONDARY OVERFLOW OUTLETS (EMERGENCY SCUPPERS AT PARAPET LEVEL) ARE REQUIRED WHERE DRAINAGE COULD BECOME BLOCKED.
THERMAL REQUIREMENTS: THE ROOF BELOW A TERRACE MUST MEET PART L U-VALUE REQUIREMENTS (0.18 W/M²K FOR FLAT ROOFS IN EXISTING BUILDINGS). WARM ROOF CONSTRUCTION (INSULATION ABOVE STRUCTURE AND VCL) IS PREFERRED — CELOTEX GA4000/XTRATHERM THIN-R/IKO ENERTHERM PIR, MINIMUM 150MM FOR 0.18 W/M²K.
Decking, Balustrade, and Costs
THE FINISH DECKING AND BALUSTRADE DETERMINE THE LOOK AND FEEL OF THE TERRACE — AND HAVE A SIGNIFICANT IMPACT ON COST AND PLANNING ACCEPTABILITY.
DECKING ON PEDESTALS: THE PREFERRED SYSTEM FOR LONDON TERRACES — DECKING BOARDS MOUNTED ON ADJUSTABLE HEIGHT PEDESTALS (RIBA SUPPORT LTD ADJUSTABLE HEAD PEDESTAL OR ETERNO IVICA SELF-LEVELLING PEDESTAL) ALLOW FALL-CORRECTED INSTALLATION WHILE PROTECTING THE WATERPROOFING MEMBRANE. MATERIAL OPTIONS: - COMPOSITE DECKING (MILLBOARD ENHANCED GRAIN, TREX ENHANCE NATURALS, CEDRAL BOARD COMPOSITE): 25-30 YEAR LIFESPAN; LOW MAINTENANCE; REALISTIC WOOD APPEARANCE; MOST POPULAR CHOICE ON LONDON PROJECTS 2024-2026. - HARDWOOD DECKING (FSC-CERTIFIED IPE, BANGKIRAI, GARAPA): PREMIUM APPEARANCE; REQUIRES ANNUAL OIL MAINTENANCE; SLIP RATING IMPORTANT (SPECIFY GROOVED/ANTI-SLIP PROFILE). - PORCELAIN PAVING TILES ON PEDESTALS: KANDLA GREY 600X600MM PORCELAIN (OR EQUIVALENT); VERY DURABLE; HEAVY; REQUIRES PEDESTAL RATED FOR HIGHER LOADS; GIVES A FLAT, LOW-MAINTENANCE SURFACE.
BALUSTRADE OPTIONS: FRAMELESS GLASS BALUSTRADE (10MM TOUGHENED SAFETY GLASS, STAINLESS STEEL SPIGOT OR CHANNEL BASE): THE MOST COMMON CHOICE FOR LONDON TERRACES — MAINTAINS VIEWS; ACCEPTED BY PLANNERS IN MOST NON-CONSERVATION AREA CONTEXTS. COST: £300-600/M SUPPLY AND INSTALL. SEMI-FRAMELESS GLASS (STAINLESS HANDRAIL + GLASS PANELS): SLIGHTLY LOWER COST; VERY SIMILAR APPEARANCE. COST: £250-450/M. MILD STEEL POWDER-COATED HANDRAIL AND VERTICAL BALUSTERS: MORE ARCHITECTURAL AESTHETIC; RAL 7016 ANTHRACITE GREY POPULAR. COST: £200-350/M.
COSTS (LONDON MARKET, 2025-2026): STRUCTURAL UPGRADE (JOIST ASSESSMENT + SISTERING OR REPLACEMENT): £1,500-5,000 DEPENDING ON EXTENT WATERPROOFING (SINGLE-PLY PVC, 20M²): £2,000-4,000 INSULATION (WARM ROOF, 20M²): £1,500-3,000 COMPOSITE DECKING ON PEDESTALS (20M²): £2,500-5,000 FRAMELESS GLASS BALUSTRADE (10M PERIMETER): £3,000-6,000 PLANNING APPLICATION (HOUSEHOLDER): £258 FEE + ARCHITECT/AGENT FEES £800-1,500 TOTAL FOR A 20M² TERRACE (TYPICAL LONDON REAR ADDITION): £12,000-25,000 INCLUDING ALL ELEMENTS
Frequently Asked Questions
Do I need planning permission to build a roof terrace in London?▼
How much weight can a flat roof support for a terrace?▼
What is the best waterproofing for a roof terrace in London?▼
How much does a roof terrace cost in London?▼
Can I have a hot tub on my London roof terrace?▼
Important Note
This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. RCB Design & Build offers free initial consultations — book your free survey.