Permitted development for ASHPs in London: PD rights and conservation area restrictions
Air source heat pumps installed at domestic properties in England benefit from a permitted development right under Part 14, Class G of the GPDO 2015 (as amended by the Town and Country Planning (General Permitted Development) (England) (Amendment) Order 2011). The PD right for domestic ASHPs applies subject to the following conditions: only one ASHP unit per property; the unit must have a sound power level of 42dB(A) or less at 1m in quiet daytime conditions (this is the MCS Planning Standards noise condition — most modern domestic ASHPs comply, but this should be confirmed with the installer at design stage); the unit must be sited at least 1m from the property boundary; the unit must not be installed on a wall or roof of the dwellinghouse or block of flats (ASHPs must be ground-mounted or mounted on an outbuilding — NOT on the building wall or roof under the PD right); the unit must be installed to minimise the effect on the external appearance of the building; the unit must be removed when no longer needed; not in the curtilage of a listed building (except for ground-mounted units that are not visible from a highway — but in practice, an ASHP in the curtilage of a listed building requires listed building consent). Conservation areas in London: the PD right for ASHPs does NOT apply in conservation areas if the unit would be installed on a wall, roof, or in a position where it is visible from a highway. Ground-mounted ASHPs in conservation areas that are not visible from a highway may retain the PD right (check with the local planning authority). In practice: many London Victorian terraces in conservation areas have limited rear garden space and no side access hidden from the highway — in these cases, planning permission may be required even for a rear garden ASHP installation if it is visible from the highway or from a neighbouring property overlooking a highway. London borough approach: different London boroughs interpret the PD rights and the conservation area restriction differently. If in doubt, submit a pre-application enquiry (PAE) to the borough's planning department before proceeding with the installation. Flats: the PD right applies to dwellinghouses — for a flat within a block, planning permission is required (the PD right does not apply), and freeholder consent will also typically be needed.
Boiler Upgrade Scheme (BUS) grant, MCS accreditation, and system sizing
Boiler Upgrade Scheme (BUS) 2025: the Boiler Upgrade Scheme (BUS) provides a £7,500 grant toward the cost of installing an air source heat pump (ASHP) or a ground source heat pump (GSHP — £7,500) or a biomass boiler (£5,000 in limited rural areas) in a residential or small commercial property in England or Wales. BUS eligibility criteria (2025): the property must have an existing boiler (gas, oil, or direct electric — the grant is for replacing a fossil fuel or direct electric heating system with a heat pump); the installer must be MCS-accredited; the property must have a current EPC (issued within the last 10 years, or within 24 months — check the current requirement on gov.uk/boiler-upgrade-scheme); the EPC must not contain recommendations for loft insulation or cavity wall insulation (unless these measures have been completed since the EPC was issued — properties with unfulfilled loft insulation or cavity wall insulation recommendations on the EPC are not eligible for BUS until those measures are completed). The £7,500 BUS grant is paid directly to the MCS-accredited installer — not to the homeowner — and is deducted from the installer's invoice to the homeowner. Application process: the MCS-accredited installer applies for the voucher on behalf of the homeowner; the voucher is valid for 3 months; the installation must be completed before the voucher expires. MCS accreditation: all ASHP installations qualifying for the BUS must be designed, installed, and commissioned by an MCS-accredited heat pump installer. The installer must also complete an MCS heat pump design survey and submit the system design (including heating load calculation and radiator/underfloor heating sizing) to MCS standards. System sizing — key design considerations for London homes: heating load calculation: using the BS EN 12831 simplified method (or a full dynamic heat loss model for better accuracy) — the ASHP output must be sized to meet the design heat loss of the property (typically 4-10kW for a London Victorian terrace, depending on insulation levels and floor area). Flow temperature: ASHPs operate most efficiently at low flow temperatures (35°C-45°C — versus 60-70°C for a traditional gas boiler). Lower flow temperatures mean larger radiators or underfloor heating may be needed. Radiator check/upgrade: existing radiators in a London Victorian terrace were typically sized for high-temperature boiler operation. When an ASHP replaces a gas boiler and the flow temperature drops to 45°C, many existing radiators will be undersized for the heat load they need to supply — requiring radiator upgrades (or oversized radiators to compensate). This is a critical design check for any London ASHP installation — a competent installer will carry out a room-by-room heat loss calculation and radiator sizing review before committing to a flow temperature target. Hot water cylinder: ASHPs do not typically include a built-in domestic hot water (DHW) storage capability — unlike a combi boiler, an ASHP requires a separate hot water storage cylinder (typically 150-300 litres for a London family home). If the property previously had a combi boiler and no hot water cylinder, the cylinder and associated pipework must be installed as part of the ASHP system — this adds cost and requires a suitable location for the cylinder (airing cupboard, utility room, or purpose-built enclosure).
ASHP installation costs for London homes in 2025 (before and after BUS grant)
Typical ASHP installation costs for a London Victorian 3-bed terrace (before BUS grant, 2025): ASHP unit supply (6-8kW output — appropriate for a well-insulated or medium-insulated London 3-bed terrace of 80-100 sq m): £3,500-£6,500 supply cost depending on brand (Mitsubishi Ecodan, Samsung Gen6, Vaillant aroTHERM, Daikin Altherma, NIBE, etc.). Hot water cylinder (200L — if not already present): £700-£1,500 supply cost. Installation (commissioning, gas-side disconnection, pipe manifold installation, electrical connections, cylinder installation, commissioning and MCS documentation): £2,500-£5,000 labour and commissioning. Radiator upgrades (if required): typically 3-8 radiators in a 3-bed terrace may need upsizing — at £300-£700 per radiator (supply and fit): £900-£5,600. External groundworks (concrete or compacted gravel pad for the ASHP unit, routed to avoid party boundary and meet 1m setback): £300-£800. Total cost before BUS grant: £9,000-£20,000 (broad range depending on system size, whether cylinder is needed, number of radiator upgrades, and specification). After £7,500 BUS grant: £1,500-£12,500 net cost. Typical mid-range net cost after BUS for a 3-bed London terrace: £6,000-£12,000. Running cost comparison (London 2025 — indicative, before any additional EV/solar interaction): gas boiler at 85% efficiency with gas at October 2025 price cap approximately 6.24p/kWh (before standing charge): heat cost approximately 7.3p/kWh of heat. ASHP at CoP 3.0 with electricity at 24.50p/kWh: heat cost approximately 8.2p/kWh of heat. Note: as of October 2025, heat pump running costs are slightly above gas boiler running costs per unit of heat at current energy prices. This can be offset by combining an ASHP with solar PV (self-consumed solar electricity at ~0p/kWh). The running cost comparison is expected to improve in favour of heat pumps as the Electricity : Gas price ratio narrows (the government's policy intent is to rebalance levies from electricity to gas over time). London-specific ASHP considerations: noise: the unit must achieve ≤42dB(A) at 1m under MCS Planning Standards conditions — always check the manufacturer's noise certification against the MCS standard. In dense London terraced streets, neighbours may be in close proximity — installer should model the noise impact at the nearest receptor (neighbour's bedroom window, nearest habitable room etc.) as part of the PD assessment. Space: the unit needs a minimum clearance of approximately 0.3-0.5m at the front and sides for airflow — the limited rear garden space of London terraces can sometimes restrict placement options while maintaining the required 1m from boundary setback.
Frequently Asked Questions
Do I need planning permission to install an air source heat pump in London?▼
What is the Boiler Upgrade Scheme grant for heat pumps in 2025?▼
How much does an air source heat pump cost to install in London in 2025?▼
Important Note
This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. RCB Design & Build offers free initial consultations — book your free survey.