Juliet Balcony vs Full Projecting Balcony: Key Distinctions
THE TWO TYPES OF BALCONY RELEVANT TO A LONDON VICTORIAN TERRACE ARE TECHNICALLY AND PLANNING-LAW DISTINCT AND SHOULD NOT BE CONFUSED:
JULIET BALCONY (ALSO CALLED A JULIET BALUSTRADE OR FRENCH BALCONY — NAMED FROM THE SHAKESPEARE BALCONY SCENE): A JULIET BALCONY IS NOT A REAL BALCONY IN THE STRUCTURAL SENSE — THERE IS NO PROJECTING PLATFORM OR DECK — A JULIET BALCONY CONSISTS ONLY OF A BALUSTRADE (A RAILING OR GLASS SCREEN) FIXED FLUSH WITH THE EXTERNAL FACE OF THE BUILDING AT FIRST-FLOOR WINDOW OR DOOR LEVEL — THE OCCUPANT CANNOT STAND ON A JULIET BALCONY (THERE IS NO PLATFORM TO STAND ON) — THE JULIET BALCONY ALLOWS A FRENCH DOOR OR FLOOR-TO-CEILING GLAZED SLIDING DOOR TO BE OPENED SAFELY AT FIRST-FLOOR LEVEL WITHOUT FALL RISK — IT GIVES THE AESTHETIC IMPRESSION OF A BALCONY AND ALLOWS FRESH AIR AND OUTLOOK FROM AN OPEN FIRST-FLOOR DOOR. PLANNING STATUS OF A JULIET BALCONY (PERMITTED DEVELOPMENT — GPDO 2015 — SCHEDULE 2 PART 1 CLASS A): A JULIET BALCONY THAT DOES NOT PROJECT BEYOND THE FACE OF THE EXTERNAL WALL (FIXED FLUSH WITH THE WALL) IS NOT CLASSED AS AN EXTENSION OR PROTRUSION UNDER GPDO 2015 AND DOES NOT REQUIRE PLANNING PERMISSION (UNLESS THE PROPERTY IS LISTED — WHERE ANY EXTERNAL ALTERATION REQUIRES LISTED BUILDING CONSENT — OR UNLESS THE PROPERTY IS IN A CONSERVATION AREA WITH AN ARTICLE 4 DIRECTION THAT CONTROLS ALTERATIONS TO THE REAR OR SIDE ELEVATION). FULL PROJECTING BALCONY (A STRUCTURALLY SUPPORTED PLATFORM PROJECTING FROM THE EXTERNAL WALL OF THE BUILDING — TYPICALLY AT FIRST-FLOOR LEVEL TO THE REAR OF A VICTORIAN TERRACE — ALLOWING THE OCCUPANT TO STAND AND SIT OUTSIDE AT FIRST-FLOOR LEVEL): THIS IS A SIGNIFICANT EXTERNAL ALTERATION THAT DOES REQUIRE PLANNING PERMISSION IN MOST CASES — BECAUSE: (1) THE BALCONY DECK PROJECTS BEYOND THE EXTERNAL WALL FACE AND IS NOT WITHIN THE PD RIGHTS FOR A CLASS A EXTENSION (PD EXTENSIONS MUST COMPLY WITH THE HEIGHT AND EXTENT LIMITS OF CLASS A — BUT A BALCONY AT FIRST-FLOOR LEVEL IS NOT AN EXTENSION OF THE FLOOR BELOW — IT IS AN ADDITION TO THE UPPER STOREY); (2) OVERLOOKING (A FIRST-FLOOR REAR BALCONY CREATES ADDITIONAL OVERLOOKING OF NEIGHBOURING REAR GARDENS AND REAR WINDOWS — LOCAL AUTHORITIES ALMOST UNIVERSALLY TREAT OVERLOOKING FROM A NEW BALCONY AS A MATERIAL PLANNING CONSIDERATION — AND MANY INNER LONDON AUTHORITIES HAVE POLICIES THAT RESTRICT OR PROHIBIT BALCONIES WHERE THEY CAUSE UNACCEPTABLE OVERLOOKING OF NEIGHBOURING PROPERTIES).
Planning Permission for Balconies in London
PLANNING PERMISSION FOR A FULL PROJECTING BALCONY ON A LONDON VICTORIAN TERRACE (HOUSEHOLDER APPLICATION — THE STANDARD PLANNING APPLICATION FOR ALTERATIONS TO A PRIVATE DWELLING): A PLANNING APPLICATION FOR A FIRST-FLOOR REAR BALCONY ON A LONDON VICTORIAN TERRACE MUST BE MADE TO THE LOCAL PLANNING AUTHORITY (THE RELEVANT LONDON BOROUGH — E.G., CAMDEN, ISLINGTON, HACKNEY, LAMBETH, WANDSWORTH, SOUTHWARK, LEWISHAM) VIA THE PLANNING PORTAL WEBSITE — HOUSEHOLDER APPLICATION FEE: £258 (CURRENT UK PLANNING PORTAL FEE — AS OF 2024-2025 — HOUSEHOLDER APPLICATION IN ENGLAND).
PLANNING CONSIDERATIONS FOR A FIRST-FLOOR REAR BALCONY IN INNER LONDON: THE MAIN PLANNING OBJECTIONS TO A REAR BALCONY ON A LONDON VICTORIAN TERRACE ARE: (1) OVERLOOKING AND LOSS OF PRIVACY (THE MOST COMMON PLANNING REFUSAL REASON FOR REAR BALCONIES IN LONDON — A FIRST-FLOOR REAR BALCONY GIVES THE OCCUPANT A STANDING OR SEATED EYE-LINE OVER THE REAR BOUNDARY FENCE AND INTO THE REAR GARDEN AND REAR WINDOWS OF THE ADJACENT OR OVERLOOKING PROPERTIES — MOST LONDON PLANNING AUTHORITIES HAVE A MINIMUM SEPARATION DISTANCE POLICY — TYPICALLY 18-21M BETWEEN A HABITABLE ROOM WINDOW OR A BALCONY AND THE NEAREST HABITABLE ROOM WINDOW IN THE ADJACENT PROPERTY — THIS MINIMUM SEPARATION DISTANCE IS ROUTINELY EXCEEDED IN INNER LONDON VICTORIAN TERRACES WHERE BACK-TO-BACK GARDEN DEPTHS ARE OFTEN ONLY 10-20M); (2) DESIGN AND VISUAL IMPACT (IN A CONSERVATION AREA OR WHERE THE STREET VISIBLE FROM THE FRONT, A BALCONY THAT IS VISIBLE FROM THE STREET OR FROM A CONSERVATION AREA NEIGHBOUR MUST BE DESIGNED TO BE SYMPATHETIC IN MATERIAL AND FORM — ANTHRACITE GREY POWDER-COATED STEEL OR GLASS BALUSTRADE ON A REAR BALCONY MAY BE ACCEPTED IN A CONSERVATION AREA WHERE A FRONT BALCONY IN SIMILAR MATERIALS WOULD NOT). (3) STRUCTURE AND STABILITY (THE STRUCTURAL ENGINEER MUST CONFIRM THAT THE EXISTING FIRST-FLOOR STRUCTURE OF THE VICTORIAN TERRACE CAN ACCEPT THE CANTILEVER LOADING OR SUPPORTED FRAME LOADING OF THE NEW BALCONY — THIS IS A BUILDING REGULATIONS MATTER — NOT A PLANNING MATTER — BUT BUILDING REGULATIONS COMPLIANCE (PART A — STRUCTURE + PART K — PROTECTION FROM FALLING) IS REQUIRED IN ADDITION TO PLANNING PERMISSION FOR A FULL BALCONY). CONSERVATION AREA: IN MANY INNER LONDON CONSERVATION AREAS, PERMITTED DEVELOPMENT RIGHTS FOR REAR BALCONIES MAY BE FURTHER RESTRICTED BY ARTICLE 4 DIRECTIONS — AND THE COUNCIL'S CONSERVATION OFFICER WILL TYPICALLY REQUIRE THAT ANY BALCONY IS DESIGNED IN A SYMPATHETIC MANNER AND DOES NOT HARM THE CHARACTER OF THE CONSERVATION AREA.
Juliet Balcony Specification and Products
A JULIET BALCONY FOR A LONDON VICTORIAN TERRACE FIRST-FLOOR REAR WALL IS MOST COMMONLY SPECIFIED IN ONE OF THREE MAIN MATERIALS: POWDER-COATED STEEL, WROUGHT IRON-STYLE CAST ALUMINIUM (FOR PERIOD CHARACTER), OR FRAMELESS TOUGHENED GLASS.
POWDER-COATED STEEL JULIET BALUSTRADE: THE MOST WIDELY USED SPECIFICATION FOR A CONTEMPORARY REAR JULIET BALCONY IN A LONDON VICTORIAN TERRACE RENOVATION 2023-2025 — A FLAT-BAR STEEL FRAME WITH VERTICAL STEEL BAR INFILL (75MM-100MM CLEAR SPACING BETWEEN BARS — COMPLYING WITH PART K 100MM SPHERE RULE — SEE BELOW) POWDER COATED IN ANTHRACITE GREY RAL 7016 (THE DOMINANT CONTEMPORARY COLOUR FOR EXTERNAL METALWORK IN LONDON RENOVATION — MATCHING BIFOLD DOORS, CRITTAL-STYLE WINDOWS, AND ALUMINIUM RAINSCREEN CLADDING); MINIMUM BALUSTRADE HEIGHT: 1,100MM ABOVE THE FLOOR LEVEL OF THE ADJACENT ROOM (OR ABOVE THE THRESHOLD OF THE DOOR WHERE THE JULIET BALCONY IS AT A DOOR THRESHOLD POSITION) — THIS IS THE MINIMUM HEIGHT PER PART K OF BUILDING REGULATIONS FOR AN EXTERNAL BALUSTRADE (THE 1,100MM MINIMUM APPLIES TO EXTERNAL BALCONIES AND EXTERNAL JULIET BALCONIES — AS OPPOSED TO THE 900MM MINIMUM FOR INTERNAL STAIRCASE BALUSTRADES). BALUSTER SPACING: MAXIMUM 100MM CLEAR BETWEEN VERTICAL MEMBERS (PART K — CHILD SAFETY — 100MM SPHERE RULE). FRAMELESS GLASS JULIET BALUSTRADE (A SINGLE PANE OF 17.52MM LAMINATED SAFETY GLASS — OR TWO PANES OF 10MM TOUGHENED LAMINATED GLASS — IN A CHANNEL OR POST-FIXINGS SYSTEM — PROVIDES AN UNOBSTRUCTED VIEW FROM THE OPEN DOOR — A MORE MINIMAL AND CONTEMPORARY AESTHETIC THAN STEEL BAR): THE MOST COMMONLY USED GLASS JULIET BALCONY SYSTEMS IN UK RESIDENTIAL RENOVATION: IBC (INTERNATIONAL BALCONY COMPANY — THE UK'S LARGEST JULIET BALCONY AND FULL BALCONY MANUFACTURER): IBC GLASS JULIET BALCONY SYSTEMS: FRAMELESS GLASS IN STAINLESS STEEL 316 CLAMPS OR IN ALUMINIUM CHANNEL — AVAILABLE IN HEIGHTS 900MM-1,100MM — TYPICALLY SUPPLIED FLATPACK FOR FITTING BY A CARPENTER OR CONTRACTOR; BALCONETTE (BALCONETTE COMPANY LTD — REDHILL, SURREY — AN ALTERNATIVE MAJOR UK JULIET BALCONY MANUFACTURER — OFFERS GLASS JULIET BALCONIES, FULL BALCONIES, AND SOLARSPAN ROOF SYSTEMS): BALCONETTE GLASS JULIET SYSTEMS AVAILABLE IN STANDARD WIDTHS 900MM TO 3,600MM — STAINLESS STEEL SPIGOT FIXINGS OR ALUMINIUM CHANNEL.
Full Balcony Structural Specification
A FULL PROJECTING BALCONY ON A LONDON VICTORIAN TERRACE (A STRUCTURALLY SUPPORTED DECK AT FIRST-FLOOR LEVEL — TYPICALLY 1.2-1.8M DEEP — 1.5-3.5M WIDE) REQUIRES A STRUCTURAL FRAME AND SUPPORT SYSTEM THAT TRANSFERS THE LOAD OF THE DECK (SELF-WEIGHT OF THE STRUCTURE + IMPOSED LOADING OF THE OCCUPANT — TYPICALLY 1.5-3.0 KN/M² LIVE LOAD FOR A DOMESTIC BALCONY PER BS EN 1991-1-1:2002) SAFELY TO THE BUILDING STRUCTURE.
STRUCTURAL OPTIONS FOR A FIRST-FLOOR REAR BALCONY ON A VICTORIAN TERRACE: (1) CANTILEVER FROM EXISTING FLOOR STRUCTURE (THE BALCONY DECK FRAME — TYPICALLY FLAT-BAR STEEL OR RHS RECTANGULAR HOLLOW SECTION STEEL FRAME — CANTILEVERS FROM THE EXISTING FIRST-FLOOR TIMBER JOIST STRUCTURE OR FROM A NEW STEEL BEAM INSERTED AT FIRST-FLOOR LEVEL): THIS APPROACH REQUIRES A STRUCTURAL ENGINEER (SE) CALCULATION TO CONFIRM THAT THE EXISTING FIRST-FLOOR JOIST STRUCTURE CAN ACCEPT THE CANTILEVER LOAD WITHOUT DEFLECTION OR FAILURE — THE CANTILEVER LENGTH IS TYPICALLY LIMITED TO 600-900MM (THE TYPICAL DEPTH OF A JULIET OR SMALL BALCONY) BEFORE THE CANTILEVER LOADING BECOMES CRITICAL FOR THE EXISTING TIMBER JOIST SECTION. (2) INDEPENDENT STEEL FRAME ON COLUMN SUPPORTS (THE BALCONY DECK IS SUPPORTED BY AN INDEPENDENT STEEL FRAME WITH COLUMN SUPPORTS TO GROUND LEVEL — ELIMINATING THE CANTILEVER LOADING ON THE EXISTING FLOOR STRUCTURE — MORE EXPENSIVE BUT STRUCTURALLY MORE CERTAIN AND ALLOWS DEEPER DECK PROJECTION OF 1.5-2.0M): FABRICATED FROM RHS HOLLOW SECTION (TYPICALLY 100X100X5MM OR 100X50X5MM) + STEEL COLUMNS (CHS — CIRCULAR HOLLOW SECTION — 76.1MM OR 88.9MM DIAMETER — 4MM WALL THICKNESS — HOT-DIP GALVANISED BS EN ISO 1461 FOR DURABILITY) — COLUMN BASES EITHER IN GROUND ON CONCRETE PAD FOUNDATION OR FIXED TO EXTERNAL WALL OF BUILDING AT GROUND FLOOR LEVEL; DECK FINISH: COMPOSITE DECKING (FIBERON GOOD LIFE — IPE-LOOK COMPOSITE DECKING — GREY OR TEAK COLOUR — MOST WIDELY USED DECK FINISH ON LONDON BALCONIES 2023-2025 — MAINTENANCE FREE — NO STAINING OR OILING REQUIRED — SLIP RESISTANT); ALTERNATIVELY: IPEE HARDWOOD DECKING (IPE — LAPACHO — THE HARDEST AND MOST DURABLE TROPICAL HARDWOOD DECKING SPECIES — FSC CERTIFIED IPES FROM A SUSTAINABLE SOURCE — VERY HIGH DURABILITY — NATURALLY SLIP RESISTANT — PREMIUM COST — OIL MAINTENANCE ANNUALLY WITH CUPRINOL WOODCARE OR OSMO UV PROTECTION OIL EXTRA 432).
Balcony Costs in London
BALCONY CONSTRUCTION COSTS (LONDON 2025 — SPECIALIST BALCONY CONTRACTOR OR STEEL FABRICATOR + CARPENTER — SUPPLY AND FIT — ALL LABOUR AND MATERIALS — EXCLUDING PLANNING PERMISSION FEES AND STRUCTURAL ENGINEER FEES).
JULIET BALCONY — POWDER-COATED STEEL BAR BALUSTRADE (FLAT BAR STEEL — ANTHRACITE GREY RAL 7016 — 1,100MM HEIGHT — SUPPLY AND FIT — INCLUDING STRUCTURAL FIXINGS TO WALL): APPROXIMATELY £800-1,800 (TYPICAL SINGLE-DOOR WIDTH — 900MM-1,200MM — SUPPLY AND FIT). JULIET BALCONY — FRAMELESS GLASS PANEL (17.52MM LAMINATED SAFETY GLASS — STAINLESS STEEL OR ALUMINIUM FIXINGS — 1,100MM HEIGHT — IBC OR BALCONETTE — SUPPLY AND FIT): APPROXIMATELY £700-1,500 (SINGLE-DOOR WIDTH — 900MM-1,200MM — SUPPLY AND FIT). FULL PROJECTING BALCONY — SMALL (1.2M DEEP X 2.0M WIDE — CANTILEVER STEEL FRAME FROM EXISTING JOIST STRUCTURE + COMPOSITE DECKING + POWDER-COATED STEEL BALUSTRADE 1,100MM — SUPPLY AND FIT): APPROXIMATELY £4,000-8,000. FULL PROJECTING BALCONY — MEDIUM (1.5M DEEP X 3.0M WIDE — INDEPENDENT STEEL FRAME ON COLUMN SUPPORTS + COMPOSITE DECKING + GLASS BALUSTRADE — SUPPLY AND FIT): APPROXIMATELY £7,000-15,000. STRUCTURAL ENGINEER FEES (REQUIRED FOR FULL PROJECTING BALCONY — CANTILEVER OR COLUMN-SUPPORTED FRAME CALCULATIONS): APPROXIMATELY £500-1,500. PLANNING APPLICATION FEE (HOUSEHOLDER APPLICATION — REQUIRED FOR FULL PROJECTING BALCONY): £258 (2024-2025 FEE). BUILDING CONTROL APPLICATION (REQUIRED FOR FULL PROJECTING BALCONY — PART A STRUCTURE + PART K SAFETY): APPROXIMATELY £200-400. TOTAL TYPICAL FIRST-FLOOR REAR BALCONY (LONDON VICTORIAN TERRACE — 1.5M DEEP X 2.5M WIDE — INDEPENDENT STEEL FRAME + COMPOSITE DECKING + GLASS BALUSTRADE — INCLUDING PLANNING + SE + BC): APPROXIMATELY £8,000-18,000 TOTAL ALL-IN.
Frequently Asked Questions
Do I need planning permission for a balcony on my London Victorian terrace?▼
What is the minimum balustrade height for a balcony in the UK?▼
What are the best materials for a balcony balustrade in a London Victorian terrace?▼
Can I add a full balcony to the rear of my London Victorian terrace?▼
How much does a balcony cost on a London Victorian terrace?▼