Contents
Boiler Types: Combi, System, and Heat-Only
The three main types of gas-fired hot water boiler used in London domestic properties each have different applications and suitability:
Combination (combi) boiler: A combi boiler heats both the central heating water and the domestic hot water on demand โ it does not need a separate hot water cylinder or a cold water storage tank in the loft. Hot water is heated instantly when a tap is opened, using the cold water mains supply directly.
Advantages of a combi: compact (the boiler itself is all that is needed, typically wall-hung); no cylinder taking up cupboard or airing cupboard space; no risk of running out of stored hot water; lower heat losses (no cylinder to keep warm); suitable for smaller London flats and houses where space is at a premium.
Limitations of a combi: the flow rate of hot water is limited by the boiler's domestic hot water output (typically 10โ13 litres/minute โ adequate for most single bathrooms but potentially insufficient for two simultaneous showers in a larger property); water pressure at the tap depends on mains cold water pressure; not suited to properties with very low mains water pressure.
System boiler: A system boiler works with a separate insulated hot water cylinder but does not require a cold water tank in the loft (it takes cold water directly from the mains, like a combi). The system boiler heats water and stores it in the cylinder, from which it is drawn when a tap is opened.
Advantages of a system boiler: can supply hot water to multiple outlets simultaneously without pressure or flow rate limitations; the cylinder provides stored hot water capacity; loft space can be freed compared with a heat-only system (no cold water tank); suited to larger London houses with multiple bathrooms or high hot water demand.
The hot water cylinder occupies an airing cupboard or utility space โ typically 150โ200 litres for a 3โ4 bedroom London house.
Heat-only (conventional/regular) boiler: A heat-only boiler requires both a hot water cylinder (typically in an airing cupboard) and a cold water storage tank in the loft. The loft tank feeds both the cylinder and the radiator system (an open-vented system).
Heat-only boilers are largely legacy systems โ they were standard in pre-1990s London properties but are now typically replaced with system or combi boilers during refurbishment. The main scenarios where a heat-only boiler might be retained or replaced like-for-like are: where the existing open-vented system is in good condition and is not being altered; or where the cold water tank provides useful water storage (for example, in a property with a history of low mains pressure).
The Condensing Boiler Requirement (Building Regulations)
Since April 2005, the Building Regulations (Approved Document L โ Conservation of Fuel and Power) have required that all new gas boilers installed in domestic properties in England and Wales must be high-efficiency condensing boilers โ boilers with a seasonal efficiency (SEDBUK 2009) of at least 86%.
A condensing boiler works by extracting additional heat from the flue gases before they are expelled โ the flue gases are cooled to below the dew point of water vapour, which condenses (producing a small amount of liquid condensate that drains away). This condensation process extracts latent heat that a non-condensing boiler would waste. The condensate must drain to a suitable drain โ typically an internal drain (preferred) or an external drain (where internal drainage is not available โ but an externally-run condensate pipe is at risk of freezing in cold weather and requires appropriate lagging and minimum pipe diameter).
In practice, virtually all modern replacement gas boilers available in the UK market are condensing boilers โ the market has standardised on the technology. A non-condensing replacement boiler would not be legal to install as a new installation in England or Wales.
Annual boiler efficiency and ErP labelling: New boilers sold in the UK must carry an ErP (Energy Related Products) efficiency label โ similar to the energy efficiency rating label on white goods. Boilers are rated from A (highest efficiency) to G. Most modern condensing combi boilers achieve an A rating (seasonal space heating efficiency of 90%+).
When is a replacement boiler required? The Building Regulations do not specify when an existing boiler must be replaced โ unlike, for example, the Minimum Energy Efficiency Standards for rental properties. An existing non-condensing boiler can continue to operate until it fails or is replaced by choice. The condensing requirement applies only at the point of replacement.
Flue Types and Location Requirements
A boiler flue expels the products of combustion (carbon dioxide, water vapour, and other combustion gases) from the boiler to outside the building. The type of flue and its location are regulated by Gas Safe and by the boiler manufacturer's installation requirements.
Room-sealed (balanced flue) โ the modern standard: Room-sealed boilers take their combustion air from outside the building through a concentric flue (a duct-within-a-duct โ inner duct for exhaust, outer duct for combustion air). The boiler is completely sealed from the room it is installed in.
Room-sealed boilers do not require a permanent ventilation opening in the room, and are the correct choice for kitchens, utility rooms, airing cupboards, and other enclosed spaces. All modern condensing gas boilers are room-sealed.
Flue terminal location rules: The flue terminal (the point where the flue exits the building) must comply with strict distance rules to avoid exhaust gases re-entering the building or being a nuisance: At least 300mm from an openable window, door, or other opening. At least 300mm below the eaves. At least 600mm from the corner of a building. At least 2,000mm above a public pavement, footpath, or walkway (where the terminal is at pedestrian level). At least 300mm from the bottom of a flat roof parapet or balcony above.
Fan-assisted (pressurised) flues on modern condensing boilers allow greater flexibility in flue routing โ longer flue runs, vertical terminations through the roof, or horizontal runs through side walls. This is important in London where many properties have limited external wall access (flats, mid-terrace houses with no side wall access) โ a vertical flue through the roof may be the only viable option.
Open-flued boilers (legacy): Older heat-only boilers were often open-flued โ they drew combustion air from the room and expelled gases via a conventional chimney or flue liner. Open-flued boilers require a permanent unobstructed ventilation opening in the room (typically a permanent vent in an external wall or floor). Open-flued boilers should not be installed in bathrooms or bedrooms. Most open-flued boilers being replaced are replaced with room-sealed condensing boilers.
Boiler Plus Regulations and Heating Controls
Since April 2018, the Boiler Plus regulations (an update to Approved Document L) have required that all new gas boiler installations in domestic properties in England include a minimum level of heating controls:
Minimum requirement for all new boiler installations: A time and temperature zone control โ meaning at least one independently programmable time schedule and temperature control for space heating (a programmable room thermostat, a smart thermostat, or an internet-connected thermostat with time programming capability).
The practical minimum is a programmable thermostat (not just a manual on/off timer) with independent temperature setpoint.
Additional requirements for combination boilers: For combination boilers with a rated output of 150kW or more (rare in domestic installations), a flue gas heat recovery device must also be fitted. For combi boilers below 150kW (the vast majority of domestic combi boilers), one of the following must be fitted in addition to the basic time and temperature zone control: Weather compensation (adjusting the boiler's flow temperature based on the external air temperature โ increasing efficiency by reducing the flow temperature when the weather is mild). Load compensation (adjusting the flow temperature based on the difference between the actual room temperature and the setpoint โ preventing over-shooting). A flue gas heat recovery device. Smart thermostat with automation and optimum start control.
Weather compensation is generally the most cost-effective additional measure for condensing boilers โ a boiler operating at lower flow temperatures (e.g. 50โ55ยฐC in mild weather, rather than 70โ75ยฐC) runs in condensing mode more of the time and can improve seasonal efficiency by 5โ10%.
Smart thermostats (Nest, Hive, Tado, Honeywell Home): Smart thermostats are the most common way to satisfy the Boiler Plus requirement for a time and temperature zone control with optional automation. They connect to the household WiFi and allow the heating schedule and temperature to be controlled via a smartphone app. Most smart thermostats also include learning algorithms, geofencing (turning the heating on when the user is approaching home), and integration with other smart home devices.
Thermostatic radiator valves (TRVs): TRVs allow individual radiators to be controlled independently, allowing the temperature in each room to be set separately. TRVs are not themselves a Boiler Plus compliance measure, but they are recommended on all radiators except the room containing the main room thermostat (where a TRV is not fitted, to allow the room temperature to be measured freely).
Gas Safety Obligations and Boiler Replacement Costs
Gas safety legal requirements:
Gas Safe registration: Any work involving gas fittings must be carried out by a Gas Safe registered engineer. This includes: Fitting a new boiler. Connecting a boiler to an existing gas supply. Modifying or extending a gas supply. Commissioning a gas boiler. Carrying out an annual gas safety inspection.
Always ask to see the engineer's Gas Safe ID card before any gas work commences. You can also verify an engineer's registration at gassaferegister.co.uk.
Annual boiler service: Gas boilers should be serviced annually by a Gas Safe registered engineer. An annual service involves: checking the flue integrity, checking all gas connections, cleaning the burner and heat exchanger, checking the safety devices and controls, and completing the manufacturer's Benchmark Commissioning Checklist (which should be retained as the service log for the appliance).
For landlords: a Landlord Gas Safety Record (CP12 certificate) must be obtained annually from a Gas Safe registered engineer for all gas appliances in rented properties. The record must be provided to tenants within 28 days of the check, and kept for at least 2 years.
Boiler replacement costs in London (2024):
Combi boiler replacement (swap, no major pipework changes): Boiler supply (good quality mid-range combi, e.g. Vaillant, Worcester Bosch, Ideal): ยฃ700โยฃ1,500 ex VAT. Labour (day rate for gas engineer, including removal and fitting): ยฃ500โยฃ900. Building Control notification (included in the Gas Safe self-certification): ยฃ0 additional. Total typical cost: ยฃ1,200โยฃ2,500 including materials and labour.
System boiler installation (including new cylinder): Boiler supply: ยฃ800โยฃ1,600. Cylinder supply (indirect unvented cylinder, 150โ200 litres): ยฃ400โยฃ700. Labour (Gas Safe engineer, cylinder installer): ยฃ700โยฃ1,200. Total typical cost: ยฃ1,900โยฃ3,500.
Full system replacement (combi or system, including power flushing the existing system): Power flushing an old system to remove sludge and debris significantly extends the life of the new boiler and heat exchanger โ recommended where the existing pipework is more than 10โ15 years old. Cost of power flush: ยฃ300โยฃ500 additional.
Heat pump as alternative: An air source heat pump (ASHP) replacement for a gas boiler typically costs ยฃ8,000โยฃ15,000 installed, before the Boiler Upgrade Scheme grant (currently ยฃ7,500). Net cost after grant: approximately ยฃ500โยฃ7,500. Heat pumps are most cost-effective where the property has high levels of wall insulation, modern double or triple glazing, and existing underfloor heating or oversized radiators. They are less suited to older London Victorian terraces with poor insulation and small original radiators.
Frequently Asked Questions
My boiler is 15 years old but still working. Should I replace it now?โผ
Do I need Building Regulations approval to replace a boiler?โผ
My boiler condensate pipe keeps freezing in winter. What is the fix?โผ
Is a heat pump better than a new gas boiler for my London Victorian terrace?โผ