Kitchen Extraction for London Victorian Terraces: Range Hoods, Ducted vs Recirculating, and Part F Compliance

Kitchen extraction — the removal of cooking odours, moisture, grease, and combustion products from the kitchen air during cooking — is a critical component of any kitchen renovation in a London Victorian terrace. The choice of extraction system (ducted, which removes air to outside via a duct through the wall or ceiling; or recirculating, which passes air through charcoal filters and returns it to the kitchen) has major implications for cooking performance, indoor air quality, maintenance, and building regulations compliance under Approved Document Part F 2021. In a Victorian terrace where the kitchen has often been relocated to a new rear extension or kitchen extension with an open-plan layout, the routing of the extraction duct — through the new flat roof, through an external wall, or via a long horizontal run to the rear — is frequently one of the most technically complex aspects of the kitchen fit. This guide covers the main extraction systems, ventilation rate requirements under Part F, duct routing, and brand specifications for London Victorian terrace kitchen renovations.

Key Takeaways

  • Part F 2021 kitchen ventilation requirements (Approved Document Part F 2021, Means of Ventilation, England): minimum boost extract rate for kitchen (ducted to outside, adjacent to hob): 30 l/s (litres per second) = 108 m³/hour — regulatory minimum only — NOT the recommended performance rate; continuous background ventilation (kitchen, part of whole-dwelling system): 13 l/s; Part F does NOT specify minimum rate for recirculating systems — requires adequate background ventilation where used; in practice: designers specify 400-700 m³/hour for a 90cm hob for adequate cooking vapour capture (BS EN 61591:2015 guidance: ~400-600 m³/hour effective for 90cm hob); higher rates needed for: open-plan kitchen (larger air volume), high-heat wok cooking, kitchen island hood (further from hob, lower capture efficiency); Part F 2021 applies to new kitchens in new build AND to material changes of use + extensions requiring Building Regulations approval — always include compliant extraction in a kitchen renovation submitted for Building Regulations
  • Ducted vs recirculating: ducted extraction is strongly preferred for Victorian terrace kitchen: (1) MOISTURE: ducted completely removes moisture from kitchen air — recirculating does NOT (charcoal filters remove odours/grease but NOT moisture — residual moisture returns to kitchen) — Victorian terraces with solid brick walls already prone to condensation — recirculating worsens condensation on cold wall surfaces; (2) PERFORMANCE: ducted through 150-200mm duct = 500-700+ m³/hour — significantly higher than recirculating limited by filter back pressure to 200-400 m³/hour; (3) MAINTENANCE: ducted = quarterly grease filter clean (dishwasher-safe, modern hoods) — recirculating = grease filter + charcoal filter replacement every 3-6 months (~£30-80/set ongoing cost; when recirculating justified: listed building (external wall penetration not permitted); conservation area (visible external grille not acceptable); genuinely impracticable duct routing; if recirculating used: ensure excellent background ventilation (trickle vents, open windows) to manage residual moisture
  • Product specifications: canopy hood (most common UK residential renovation): Neff D95IMW5N0B (Neff/BSH Home Appliances, 90cm, 750 m³/hour ducted, flat glass, touch control, dishwasher-safe grease filter, Neff Home Connect) — most frequently specified mid-to-high end hood in London residential kitchen renovation 2020s; Siemens LC91BBM50B (Siemens/BSH, 90cm, 755 m³/hour ducted, chimney style — sister brand to Neff, same BSH manufacturing); AEG DVB5960HB (AEG/Electrolux, 90cm, 695 m³/hour, touchscreen); ceiling extractor/island: Elica Nikolatesla Flat (Elica SpA, Fabriano Italy, flush ceiling mount, invisible when off, 600x600mm or 900x900mm, 700 m³/hour ducted — leading premium ceiling extractor brand UK high-end residential); downdraft: Bora Pure (Bora GmbH, Raubling Bavaria, combined glass ceramic hob + integrated downdraft extractor drawing air through hob surface, 700 m³/hour max ducted, specialist duct routing through worktop→unit→floor/wall)
  • Duct routing and sizing: minimum duct diameter: 150mm round duct (Spiroduct galvanised steel, Primaduct, Spiralite, or flexible aluminium e.g. Dantherm Ridgiduct) for 60-90cm hood up to 600 m³/hour, duct run up to 2-3m effective, max 1-2 bends; 200mm round duct for: 90cm+ hood >600 m³/hour, duct run >3m effective, >2 bends, island ceiling extractor, downdraft; AVOID 100mm duct (bathroom fan duct) — insufficient for any kitchen hood — excessive back pressure, noise, dramatically reduced airflow, invalidates manufacturer's rated extraction; bend allowances: 90° bend = +1.0-1.5m equivalent straight length; 45° bend = +0.5-0.8m; external termination: Manrose CF100G or equivalent low-resistance gravity back-draught shutter grille (NOT standard plastic push-fit wall grille — causes back pressure); wall penetration: diamond core drill 162mm (150mm duct) or 212mm (200mm duct) through 215mm Victorian brick; flat roof penetration: Duraflex round pipe flashing (Sarnafil/EPDM/PVC compatible) or specialist flat roof duct terminal — welded/mechanically fastened to roof membrane — NOT sealant only — any gap = water ingress into kitchen ceiling
  • Costs London 2025 (electrical/kitchen fit, supply+fit): standard canopy hood (Neff D95IMW5N0B, 90cm ducted, 150mm duct through rear wall ≤2m, core drill, external grille, electrical connection): hood ~£400-600 + install ~£300-600 = total ~£700-1,200; complex duct run (through flat roof, 4-5m run, 2-3 bends, weathertight roof penetration): add ~£300-600; premium ceiling extractor island (Elica Nikolatesla Flat, 90x90cm, ducted through ceiling, specialist install): hood ~£1,500-3,500 + install ~£600-1,200 = total ~£2,100-4,700; Bora Pure downdraft hob+extractor (specialist duct through floor): supply ~£2,000-4,500 + install ~£800-1,500 = total ~£2,800-6,000; recirculating hood (no duct, charcoal filters, supply+fit): ~£300-800 all-in (but ongoing charcoal filter ~£30-80 every 3-6 months); kitchen extraction almost always specified as part of wider kitchen renovation — included in overall kitchen fit contractor's scope

Part F 2021 Kitchen Ventilation Rates

APPROVED DOCUMENT PART F 2021 (MEANS OF VENTILATION — ENGLAND — THE BUILDING REGULATIONS 2010 — PART F1 — VENTILATION FOR DWELLINGS) REQUIRES KITCHEN SPACES IN A DWELLING TO BE PROVIDED WITH A MINIMUM LEVEL OF EXTRACT VENTILATION TO REMOVE MOISTURE AND POLLUTANTS FROM COOKING — WITH SPECIFIC MINIMUM AIRFLOW RATES DEPENDING ON WHETHER THE VENTILATION IS PROVIDED BY A COOKER HOOD/EXTRACTOR OR BY GENERAL KITCHEN VENTILATION.

PART F 2021 — EXTRACT VENTILATION IN A KITCHEN: MINIMUM EXTRACT RATE FOR A KITCHEN (WHERE THE COOKER IS ADJACENT TO AN EXTERNAL WALL OR DUCT AND CAN BE DUCTED TO OUTSIDE — DUCTED EXTRACTION): 30 L/S (LITRES PER SECOND — EQUIVALENT TO 108 M³/HOUR) ADJACENT TO THE HOB — THIS IS THE MINIMUM BOOST RATE THAT THE EXTRACTION SYSTEM MUST ACHIEVE — IT DOES NOT MEAN 30 L/S CONTINUOUS BACKGROUND VENTILATION — IT MEANS THE EXTRACTION SYSTEM MUST BE CAPABLE OF EXTRACTING AT LEAST 30 L/S AT ITS BOOST SETTING WHEN IN USE FOR COOKING. CONTINUOUS BACKGROUND VENTILATION (FOR THE KITCHEN AS PART OF THE WHOLE DWELLING VENTILATION SYSTEM UNDER PART F): A MINIMUM CONTINUOUS BACKGROUND VENTILATION RATE OF 13 L/S IS REQUIRED FOR THE KITCHEN (AS PART OF THE WHOLE DWELLING TRICKLE VENTILATION OR DECENTRALISED MECHANICAL EXTRACT VENTILATION (DMEV) SYSTEM — SEE VENTILATION GUIDE). NOTE: 30 L/S IS THE REGULATORY MINIMUM — IN PRACTICE, MOST PROFESSIONAL KITCHEN DESIGNERS SPECIFY A SIGNIFICANTLY HIGHER EXTRACTION RATE TO ADEQUATELY CAPTURE ALL COOKING VAPOUR AT THE HOB: BRITISH STANDARD BS EN 61591:2015 (DOMESTIC COOLING HOODS — PERFORMANCE TESTING FOR COOKING HOOD/RANGE HOOD PERFORMANCE) SPECIFIES A GUIDANCE EFFECTIVE EXTRACTION RATE OF APPROXIMATELY 400-600 M³/HOUR (110-165 L/S) FOR A 90CM WIDE HOB — A FAR HIGHER RATE THAN THE PART F MINIMUM. PART F 2021 DOES NOT SPECIFY A REQUIREMENT FOR RECIRCULATING (NON-DUCTED) EXTRACT IN A KITCHEN — HOWEVER IT DOES ALLOW RECIRCULATING SYSTEMS WHERE DUCTING TO OUTSIDE IS NOT PRACTICABLE, PROVIDED THAT ADEQUATE BACKGROUND VENTILATION (TRICKLE VENTS, OPEN WINDOWS) IS AVAILABLE TO MANAGE THE RESIDUAL MOISTURE THAT RECIRCULATING FILTRATION DOES NOT REMOVE.

Ducted vs Recirculating Extraction

THE CHOICE BETWEEN DUCTED EXTRACTION (AIR IS CARRIED VIA A DUCT — TYPICALLY 150MM OR 200MM ROUND DUCT OR EQUIVALENT FLAT RECTANGULAR DUCT — FROM THE EXTRACTOR HOOD TO AN OUTSIDE GRILLE ON THE REAR OR SIDE WALL OF THE PROPERTY, OR THROUGH THE FLAT ROOF OF A REAR EXTENSION) AND RECIRCULATING EXTRACTION (AIR IS PASSED THROUGH GREASE FILTERS AND ACTIVATED CHARCOAL FILTERS AND RETURNED TO THE KITCHEN SPACE) IS THE SINGLE MOST IMPORTANT TECHNICAL DECISION IN KITCHEN EXTRACTION SPECIFICATION.

DUCTED EXTRACTION (STRONGLY PREFERRED FOR ALL SERIOUS KITCHEN SPECIFICATION — PART F MINIMUM DUCTED EXTRACTION RATE 30 L/S / 108 M³/HOUR — TYPICAL SPECIFIED RATE 400-700 M³/HOUR FOR OPEN-PLAN KITCHEN): ADVANTAGES: (1) REMOVES MOISTURE, GREASE, ODOURS, AND COMBUSTION PRODUCTS COMPLETELY FROM THE KITCHEN AIR — RECIRCULATING DOES NOT REMOVE MOISTURE — MOISTURE MUST BE REMOVED TO PREVENT CONDENSATION ON WALLS AND WINDOWS IN A VICTORIAN TERRACE (WHICH IS ALREADY PRONE TO CONDENSATION DUE TO SOLID BRICK WALLS AND POOR ORIGINAL VENTILATION); (2) PERFORMANCE: DUCTED EXTRACTION USING A 150MM OR 200MM ROUND DUCT (MINIMUM RECOMMENDED DIAMETER — 100MM DUCT IS TOO SMALL FOR A HIGH-PERFORMANCE HOOD AND CREATES EXCESSIVE NOISE AND BACK PRESSURE) CAN ACHIEVE 500-1000 M³/HOUR EXTRACTION RATE — FAR HIGHER THAN ANY RECIRCULATING SYSTEM; (3) NOISE: DUCTED EXTRACTION IS GENERALLY QUIETER THAN RECIRCULATING — THE MOTOR WORKS LESS HARD AGAINST A CLEAR AIR PATH COMPARED TO THE BACK PRESSURE OF RECIRCULATING FILTERS. RECIRCULATING EXTRACTION (USED WHERE DUCTING TO OUTSIDE IS NOT PRACTICABLE — LISTED BUILDING/CONSERVATION AREA EXTERIOR CANNOT BE PENETRATED — OR WHERE DUCT ROUTING IS EXCESSIVELY LONG OR COMPLEX): DISADVANTAGES: DOES NOT REMOVE MOISTURE — RESIDUAL MOISTURE RETURNS TO THE KITCHEN AIR AFTER CHARCOAL FILTRATION — IN A VICTORIAN TERRACE WITH SOLID WALLS AND POOR BACKGROUND VENTILATION, THIS CAN CAUSE CONDENSATION PROBLEMS; CHARCOAL FILTERS REQUIRE REPLACEMENT EVERY 3-6 MONTHS (DEPENDING ON COOKING INTENSITY) AT A COST OF £30-80 PER SET — RECIRCULATING IS NOT MAINTENANCE-FREE; ODOUR REMOVAL IS LESS COMPLETE THAN DUCTED; EXTRACTION RATE IS TYPICALLY LIMITED TO 200-400 M³/HOUR IN RECIRCULATING MODE (LOWER THAN DUCTED — DUE TO FILTER BACK PRESSURE).

Canopy Hoods, Ceiling Extractors, and Downdraft Systems

THE MARKET FOR KITCHEN EXTRACTION HOODS AND SYSTEMS IS DIVIDED BETWEEN SEVERAL MAIN PRODUCT TYPES — EACH WITH DIFFERENT INSTALLATION REQUIREMENTS, DUCT ROUTING OPTIONS, AND PERFORMANCE CHARACTERISTICS.

CANOPY HOOD (THE MOST COMMON EXTRACTION SYSTEM IN UK RESIDENTIAL KITCHEN RENOVATION — A STAINLESS STEEL, GLASS, OR CHIMNEY-STYLE CANOPY FIXED UNDER OR INSIDE A CABINET ABOVE THE HOB — CONNECTED TO A 150MM OR 200MM ROUND OR FLAT RECTANGULAR DUCT THAT ROUTES TO THE EXTERIOR): NEFF D95IMW5N0B (NEFF — BSH HOME APPLIANCES — 90CM — 750 M³/HOUR DUCTED — FLAT GLASS CANOPY — TOUCH CONTROL — DISHWASHER-SAFE GREASE FILTER — PART OF NEFF HOME CONNECT CONNECTED HOME SYSTEM — THE MOST FREQUENTLY SPECIFIED MID-TO-HIGH END EXTRACTION HOOD IN LONDON RESIDENTIAL KITCHEN RENOVATION IN THE 2020S — TYPICALLY SPECIFIED WITH NEFF INDUCTION HOB NEFF T66PHX4L0 OR SIMILAR NEFF HOB): SIEMENS LC91BBM50B (SIEMENS HOME — BSH HOME APPLIANCES — 90CM — 755 M³/HOUR DUCTED — CHIMNEY HOOD — SIMILAR SPEC TO NEFF — SIEMENS AND NEFF ARE SISTER BRANDS OF BSH — BOTH MANUFACTURED AT THE SAME BSH PLANTS); AEG DVB5960HB (AEG/ELECTROLUX — 90CM CHIMNEY HOOD — 695 M³/HOUR DUCTED — TOUCHSCREEN — DISHWASHER-SAFE GREASE FILTER). CEILING EXTRACTOR (ISLAND EXTRACTOR — A CEILING-MOUNTED EXTRACTION UNIT SUSPENDED ABOVE A KITCHEN ISLAND — REQUIRES THE DUCT TO BE ROUTED THROUGH THE CEILING VOID AND ABOVE — SUITABLE WHERE THE HOB IS ON AN ISLAND AND A WALL-MOUNTED HOOD IS NOT POSSIBLE): ELICA NIKOLATESLA FLAT (ELICA S.P.A — FABRIANO, ITALY — THE LEADING PREMIUM CEILING EXTRACTOR BRAND IN THE UK HIGH-END RESIDENTIAL KITCHEN MARKET — NIKOLATESLA FLAT = FLUSH-MOUNTED FLAT CEILING EXTRACTOR — INTEGRATED INTO THE CEILING — INVISIBLE WHEN NOT IN USE — 600MM X 600MM OR 900MM X 900MM VERSIONS — 700 M³/HOUR DUCTED). DOWNDRAFT EXTRACTOR (RISES FROM BELOW OR BEHIND THE HOB LEVEL WHEN IN USE — DUCTED THROUGH THE WORKTOP OR FLOOR): BORA PURE (BORA GMBH & CO KG — RAUBLING, BAVARIA — THE PREMIUM DOWNDRAFT HOB EXTRACTOR BRAND — BORA PURE COMBINES A GLASS CERAMIC HOB WITH AN INTEGRATED EXTRACTOR THAT DRAWS AIR DOWN THROUGH THE HOB SURFACE ITSELF — 700 M³/HOUR MAX DUCTED — VERY UNUSUAL DUCT ROUTING: THROUGH THE WORKTOP SURFACE, THEN THROUGH THE KITCHEN UNIT CARCASS, THEN BELOW THE FLOOR OR THROUGH THE WALL — REQUIRES SPECIALIST INSTALLATION).

Duct Routing in a London Victorian Terrace

THE ROUTING OF THE EXTRACTION DUCT FROM THE KITCHEN HOOD TO THE EXTERNAL GRILLE IS ONE OF THE MOST PRACTICALLY COMPLEX ASPECTS OF KITCHEN EXTRACTION IN A LONDON VICTORIAN TERRACE — PARTICULARLY WHERE THE KITCHEN HAS BEEN RELOCATED TO A NEW REAR EXTENSION, OPEN-PLAN LAYOUT, OR KITCHEN-DINER EXTENDING TO THE FULL REAR WALL.

MINIMUM DUCT DIAMETER: 150MM ROUND DUCT (SPIRODUCT GALVANISED STEEL OR EQUIVALENT — PRIMADUCT, SPIRALITE, FLEXIBLE ALUMINIUM DUCT SUCH AS DANTHERM OR RENSON RIDGIDUCT) — 150MM IS THE MINIMUM FOR A 90CM HOOD AT 500-700 M³/HOUR — USE 200MM DUCT WHERE THE RUN IS LONGER THAN 2-3M OR WHERE THERE ARE MORE THAN 2 BENDS. MAXIMUM DUCT RUN LENGTH: PER BS 5440-2:2000 (INSTALLATION OF FLUES AND VENTILATION) AND KITCHEN HOOD MANUFACTURER INSTALLATION REQUIREMENTS — THE EFFECTIVE DUCT LENGTH (STRAIGHT RUN + BEND ALLOWANCES) SHOULD NOT EXCEED 3-5M FOR A 150MM DUCT — EACH 90° BEND ADDS AN EQUIVALENT STRAIGHT LENGTH OF APPROXIMATELY 1.0-1.5M; EACH 45° BEND APPROXIMATELY 0.5-0.8M. EXTERNAL GRILLE: STANDARD PLASTIC PUSH-FIT WALL GRILLE (NOT ADEQUATE FOR HIGH-PERFORMANCE EXTRACTION — CAUSES BACK PRESSURE AND NOISE): SPECIFY INSTEAD A LOW-RESISTANCE GRAVITY BACK-DRAUGHT SHUTTER GRILLE (MANROSE CF100G OR EQUIVALENT — GRAVITY-FLY LOUVRE OPENS UNDER POSITIVE AIRFLOW, CLOSES BY GRAVITY WHEN EXTRACTOR IS OFF — PREVENTS COLD AIR BACK-FLOW AND BIRD ENTRY). WALL PENETRATION (REAR ELEVATION OF VICTORIAN TERRACE — BRICK): DIAMOND CORE DRILL 162MM (FOR 150MM DUCT) OR 212MM (FOR 200MM DUCT) — CUTTING THROUGH 215MM VICTORIAN BRICK WALL — TYPICALLY REQUIRES A DIAMOND CORE DRILL HIRE OR SPECIALIST DRILLING CONTRACTOR — NOT A HAMMER DRILL AND SDS BIT. FLAT ROOF PENETRATION (REAR EXTENSION FLAT ROOF — THE MOST COMMON ROUTE IN A CONTEMPORARY KITCHEN EXTENSION): CORE DRILL THROUGH ROOF DECK (IF STRUCTURAL CONCRETE) OR JIGSAW CUT THROUGH OSB/PLY DECK — WEATHER-TIGHT ROOF PENETRATION USING A DURAFLEX ROUND PIPE ROOF PENETRATION (SARNAFIL-COMPATIBLE) OR FLATROOF DUCT TERMINAL — CRITICALLY: THE ROOF PENETRATION MUST BE FULLY WEATHERPROOFED — A SARNAFIL WELDED OR EPDM FLASHED DUCT COLLAR — NOT JUST SEALANT AROUND THE DUCT — ANY LEAK AT THIS POINT WILL CAUSE INTERNAL WATER INGRESS INTO THE KITCHEN CEILING.

Kitchen Extraction Costs in London

KITCHEN EXTRACTION COSTS (LONDON 2025 — ELECTRICAL/KITCHEN FIT CONTRACTOR — SUPPLY AND FIT — LABOUR AND MATERIALS).

STANDARD CANOPY HOOD (NEFF D95IMW5N0B OR EQUIVALENT SIEMENS/AEG — 90CM — DUCTED — 150MM DUCT THROUGH REAR WALL — UP TO 2M DUCT RUN — INCLUDING DUCT, DIAMOND CORE DRILL, EXTERNAL GRILLE, ELECTRICAL CONNECTION): NEFF D95IMW5N0B HOOD SUPPLY COST: APPROXIMATELY £400-600 (TRADE PRICE FROM AO.COM, EURONICS, JOHN LEWIS) + INSTALLATION LABOUR: £300-600 FOR STANDARD DUCTED INSTALLATION (DUCT THROUGH REAR WALL, UP TO 2M) = TOTAL APPROXIMATELY £700-1,200; COMPLEX DUCT RUN (THROUGH FLAT ROOF, 4-5M DUCT RUN WITH 2-3 BENDS, WEATHERTIGHT ROOF PENETRATION): ADD £300-600 TO THE ABOVE. PREMIUM CEILING EXTRACTOR — ISLAND (ELICA NIKOLATESLA FLAT OR EQUIVALENT — 90X90CM — FLUSH CEILING MOUNTED — DUCTED THROUGH CEILING VOID AND ROOF — SPECIALIST INSTALLATION): HOOD SUPPLY: APPROXIMATELY £1,500-3,500 + INSTALLATION: £600-1,200 (CEILING VOID DUCT ROUTING, ROOF PENETRATION, PLASTERBOARD INFILL AROUND HOOD) = TOTAL APPROXIMATELY £2,100-4,700. BORA PURE OR EQUIVALENT DOWNDRAFT HOB+EXTRACTOR (SUPPLY AND FIT — INTEGRATED DOWNDRAFT HOB — SPECIALIST INSTALLATION — DUCT THROUGH FLOOR/BELOW UNIT): SUPPLY: £2,000-4,500 + INSTALLATION: £800-1,500 (SPECIALIST DUCT ROUTING THROUGH FLOOR) = TOTAL APPROXIMATELY £2,800-6,000. RECIRCULATING HOOD (ELICA BLADE OR EQUIVALENT 90CM — NO DUCT — CHARCOAL FILTERS — SUPPLY AND FIT): £300-800 ALL-IN INCLUDING ELECTRICAL CONNECTION (LOW INSTALLATION COST VS DUCTED — NO CORE DRILL OR DUCT ROUTING — BUT ONGOING CHARCOAL FILTER REPLACEMENT COST: £30-80 EVERY 3-6 MONTHS).

Frequently Asked Questions

What is the minimum extraction rate for a kitchen under Part F 2021?
Under Approved Document Part F 2021 (Means of Ventilation, England), the minimum extract ventilation rate for a kitchen is: boost rate (when cooking, with extraction adjacent to the hob and ducted to outside): 30 l/s (litres per second — equivalent to 108 m³/hour) adjacent to the hob — this is the minimum the extraction system must achieve at its boost setting; continuous background ventilation (kitchen, as part of whole-dwelling ventilation system): 13 l/s continuous; important note: 30 l/s (108 m³/hour) is the regulatory minimum — it is NOT the recommended extraction rate for good cooking performance; in practice, most kitchen designers specify 400-700 m³/hour for a 90cm wide hob to adequately capture all cooking vapour at source; British Standard BS EN 61591:2015 (domestic cooking hoods) suggests approximately 400-600 m³/hour effective extraction for a 90cm hob; higher rates are needed for an open-plan kitchen (where the cooking vapour has a larger volume of air to disperse into), for wok/induction cooking at high heat, or for a kitchen island (where the extraction hood is further from the hob and loses more air before capture); Part F does not specify a minimum rate for recirculating (non-ducted) systems, but does require that adequate background ventilation (trickle vents, open windows) is available where a recirculating system is used to manage residual moisture.
Should I use ducted or recirculating extraction in a Victorian terrace kitchen?
For a London Victorian terrace kitchen: ducted extraction is strongly preferred — the key reasons: (1) moisture removal: ducted extraction completely removes moisture from the kitchen air — recirculating extraction does NOT remove moisture (charcoal filters remove odours but not moisture) — Victorian terraces with solid brick walls are already prone to condensation (the walls are cold and cannot breathe well in modern sealed kitchens) — residual cooking moisture returning to the kitchen air from a recirculating system will worsen condensation on cold wall surfaces and windows; (2) performance: ducted extraction through a 150-200mm duct can achieve 500-700+ m³/hour — significantly more powerful than recirculating systems limited by filter back pressure to 200-400 m³/hour; (3) maintenance: ducted systems require only quarterly grease filter cleaning (dishwasher-safe on most modern hoods) — recirculating systems also require charcoal filter replacement every 3-6 months (£30-80 per set); when recirculating is justified: listed building where external wall penetration is not permitted; conservation area where an external grille on the front or visible elevation is not acceptable; where duct routing is genuinely impracticable (excessively long run, no access to roof or external wall); ensure excellent background ventilation (open windows, trickle vents) is available if using recirculating to manage residual moisture.
What size duct do I need for a kitchen extractor?
Minimum recommended duct size for a kitchen extractor in a London Victorian terrace kitchen renovation: 150mm round duct (Spiroduct galvanised steel, Primaduct, Spiralite, or equivalent rigid galvanised duct) for: 60-90cm hood rated up to 600 m³/hour with a short duct run (up to 2-3m effective length, max 1-2 bends); 200mm round duct for: 90cm+ hood rated at 600-1000 m³/hour; duct runs longer than 3m effective length; more than 2 bends in the duct run; kitchen island ceiling extractor (Elica Nikolatesla) or downdraft (Bora Pure); avoid 100mm duct: 100mm duct (100mm push-fit plastic duct — as used for bathroom extract fans) is insufficient for a kitchen extractor hood — the small diameter creates excessive back pressure, dramatically reduces airflow, causes noise, and invalidates the extraction rate quoted by the hood manufacturer; each 90° bend in the duct adds an equivalent straight length of approximately 1.0-1.5m — each 45° bend adds 0.5-0.8m — calculate effective duct length to check whether 150mm or 200mm is required; external termination: use a low-resistance gravity back-draught shutter grille (Manrose CF100G or equivalent) — NOT a standard plastic push-fit wall grille — the gravity louvre opens under positive airflow from the extractor and closes by gravity when the extractor is off (prevents cold air back-draught and bird entry).
Can I put the extraction duct through the roof of my rear extension?
Yes — routing the kitchen extraction duct through the flat roof of a rear extension is a common and technically sound approach where: the kitchen has been extended to the rear and the external rear wall of the original house is no longer accessible for a wall penetration; the duct run to the rear wall is excessively long (>3-4m effective length for a 150mm duct); a roof penetration gives a shorter, more direct duct route; technical requirements for a flat roof duct penetration: diamond core drill (for concrete roof) or jigsaw cut (for OSB/ply timber deck); install a weathertight duct collar — Duraflex round pipe flashing (compatible with Sarnafil, EPDM, and PVC flat roof membranes) or a specialist flat roof duct terminal — this must be professionally installed and fully weatherproofed — do NOT rely on sealant alone around the duct; the duct collar must be welded or mechanically fastened and sealed to the roof membrane — any gap = water ingress into the kitchen ceiling; the external duct terminal on top of the roof should be a 180° turn-down cowl or directional grille to prevent rain ingress and bird entry from above; maintenance access to the roof duct terminal should be planned from the outset — some duct terminals on flat roofs are difficult to access for cleaning; the core drill through the roof should be sealed with expanding foam inside before the duct collar is installed to prevent cold air bridging around the duct.
How much does kitchen extraction installation cost in London?
Kitchen extraction costs London 2025 (electrical/kitchen fit contractor, supply+fit, labour+materials): standard canopy hood (Neff D95IMW5N0B or equivalent Siemens/AEG, 90cm, ducted, 150mm duct through rear wall, up to 2m duct run, including duct, diamond core drill, external grille, electrical connection): hood cost ~£400-600 + installation ~£300-600 = total approximately £700-1,200; complex duct run (through flat roof, 4-5m run with 2-3 bends, weathertight roof penetration): add £300-600 to above; premium ceiling extractor island (Elica Nikolatesla Flat or equivalent, 90x90cm, ducted through ceiling void, specialist installation): hood ~£1,500-3,500 + installation ~£600-1,200 = total approximately £2,100-4,700; Bora Pure downdraft hob+extractor (supply+fit, specialist duct routing through floor): supply ~£2,000-4,500 + installation ~£800-1,500 = total approximately £2,800-6,000; recirculating hood (no duct, charcoal filters, supply+fit, no core drill): £300-800 all-in (low install cost but ongoing charcoal filter cost £30-80 every 3-6 months); note: kitchen extraction is rarely specified as a standalone project — it is almost always part of a wider kitchen renovation and the extraction installation cost is included in the overall kitchen fit contractor's scope.

Important Note

This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. RCB Design & Build offers free initial consultations — book your free survey.