Types of Noise: Airborne vs Impact
Airborne sound: noise carried through the air — conversation, music, television, traffic noise. Airborne sound insulation is measured in dB (decibels) and the performance of a separating wall or floor is rated by its DnT,w value (weighted standardised level difference). Higher dB values indicate better insulation. Building Regulations Part E requires a minimum DnT,w+Ctr of 45 dB for walls between dwellings in conversions (purpose-built flats have a 43 dB minimum).
Impact sound: noise from physical impact on a structure — footsteps, dropped objects, dragged furniture. Impact sound is measured as L'nT,w. Lower values indicate better performance (the noise level transmitted is lower). Building Regulations Part E requires a maximum L'nT,w of 62 dB for floors between dwellings in conversions.
When Do Building Regulations Part E Apply?
Part E of the Building Regulations applies to:
- New dwellings (houses and flats)
- Conversions of houses to flats (material change of use)
- Hotels and student accommodation
Part E does not apply to:
- Refurbishment within an existing single dwelling (works within the same dwelling)
- Like-for-like replacement of existing elements where no material change is being made
Key implication: if you are converting a house to two flats, all separating floors and walls must meet Part E performance requirements, and pre-completion acoustic testing (or Robust Detail specification) is needed to demonstrate compliance.
Solutions for Party Walls
Independent wall lining (resilient isolation): the most common approach for improving party wall performance in conversions and refurbishments. A new lightweight steel frame or timber batten system is constructed approximately 25 to 50mm away from the party wall, with acoustic mineral wool quilt between and behind the frame, and two or more layers of acoustic plasterboard applied. The lining is isolated from the party wall (ideally not making rigid contact) to interrupt vibration transmission.
Performance expectation: a well-constructed independent wall lining can add 5 to 15 dB to the airborne performance of an existing masonry party wall. A dense brick party wall already has reasonable inherent mass; the lining adds decoupling and absorption.
Solutions for Floors (Impact and Airborne)
Acoustic floating floor: a resilient layer (mineral wool quilt, rubber mat, or composite product such as Regupol or acoustic cradle system) installed beneath a new floor screed or deck, decoupled from the structural floor. This addresses both impact and airborne sound. The system must be truly floating — any rigid connection (such as a skirting board fixed through the floor finish to the subfloor) creates a flanking path that undermines performance.
Ceiling treatment below (independent ceiling): a new ceiling hung on resilient bars (metal resilient channels) with acoustic mineral wool between the joists and two layers of acoustic plasterboard. The resilient bar decouples the ceiling from the structure above. An independent ceiling hung on hangers below the existing ceiling (with an air gap) is the most effective approach.
Combined system: for a floor/ceiling assembly between two flats, the combination of a floating floor above and an independent ceiling below typically achieves the best performance.
Flanking Sound
Flanking sound — noise transmitted via indirect paths (through the floor at the wall base, through the wall above the floor, through service penetrations) rather than directly through the separating element — is the most common reason acoustic performance falls short in practice. Flanking control requires:
- Continuous skirting boards that do not bridge the floating floor at the perimeter
- Sealing of all service penetrations through separating elements
- Acoustic mastic at junctions between elements
Pre-Completion Testing
Where Part E compliance is required (house to flat conversion), acoustic performance must be demonstrated. Two routes are available:
- Robust Details: specify a Robust Detail-approved construction system for floors and walls. If built correctly, no testing is needed (a small registration fee applies)
- Pre-completion acoustic testing: an acoustic engineer carries out sound insulation testing before the dwellings are occupied, producing a test report for Building Control sign-off
Typical Costs
- Independent acoustic wall lining system (supply and fix, per m2): £40 to £80/m2
- Acoustic floating floor system (resilient layer + screed or chipboard deck, per m2): £35 to £70/m2
- Independent acoustic ceiling system (resilient bar + acoustic plasterboard, per m2): £40 to £80/m2
- Pre-completion acoustic test (per pair of separating elements): £400 to £700
Want advice on your own project?
Pick whatever suits you. We'll look at what you have (drawings, photos or quotes) and tell you honestly what the next step should be.
Prefer to phone? Call +44 7359 872594.
Important Note
This guide is for general information only. Building regulations, planning rules, and legal requirements change regularly and vary by local authority. Always seek professional advice specific to your project and location. To talk through your own project, book a project review.
Was this guide helpful? Share it:
Have a question about your project?
Message us on WhatsApp or call — we reply during working hours (Mon–Fri 8am–6pm, Sat 9am–2pm).